Harriman Lines 2-8-0 "Consolidation" Locomotives of the USA


Class Details by Steve Llanso of Sweat House Media

Class Heavy Consolidation C-187 (Locobase 5342)

Data from"Report of CommitteE on Power-Chicago, Rock Island & Pacific Railway-Descriptions of Standard Types of Locomotives," American Engineer and Railroad Journal, Volume 79 ( March 1905), pp. 84-86.

Part of the so-called "Harriman Common Standard", this class was completed without a superheater. Using the same firebox as the HCS Atlantics and Light Pacifics, the design had a middling number of tubes for a 2-8-0 of this size. Unlike the other two road engines of this policy, however, these were relatively big engines for their time and wheel arrangements and had comparatively big boilers for their cylinder volume.

Locobase 3165 (Southern Pacific) and 4399 (Union Pacific) are examples of this design. See Locobase 5340 for introduction to the HCS idea.

Specifications by Steve Llanso of Sweat House Media
ClassHeavy Consolidation C-187
Locobase ID5342
RailroadHarriman Lines
CountryUSA
Whyte2-8-0
Number in Class
Road Numbers
GaugeStd
Number Built
BuilderBurnham, Williams & Co
Year1904
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase15.67'
Engine Wheelbase24.33'
Ratio of driving wheelbase to overall engine wheebase 0.64
Overall Wheelbase (engine & tender)55.98'
Axle Loading (Maximum Weight per Axle)
Weight on Drivers187000 lbs
Engine Weight208000 lbs
Tender Light Weight135050 lbs
Total Engine and Tender Weight343050 lbs
Tender Water Capacity9000 gals
Tender Fuel Capacity (oil/coal)3535 gals
Minimum weight of rail (calculated)78 lb/yard
Geometry Relating to Tractive Effort
Driver Diameter57"
Boiler Pressure200 psi
Cylinders (dia x stroke)22" x 30"
Tractive Effort43305 lbs
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.32
Heating Ability
Firebox Area177 sq. ft
Grate Area49.50 sq. ft
Evaporative Heating Surface3403 sq. ft
Superheating Surface
Combined Heating Surface3403 sq. ft
Evaporative Heating Surface/Cylinder Volume257.82
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation9900
Same as above plus superheater percentage9900
Same as above but substitute firebox area for grate area35400
Power L16173
Power MT291.10


If you have any railroad data such as diagram books, rail station plans or anything else that you would be willing to share, please contact us.