Ballymena & Larne 0-6-0 Locomotives in Ireland


Class Details by Steve Llanso of Sweat House Media

Class Q (Locobase 10225)

Data from "Narrow-Gauge Locomotives of the Belfast and Northern Counties RY," The Locomotive Magazine, Vol VII (May 1902), p. 92. Boiler pressure is an estimate. Works numbers were 1700-1701.

With the first of the two 2-4-0Ts from BP (Locobase 10224), the B & L also received these two more powerful goods engines. Both were taken into the Belfast & Northern Counties in 1889 where they were renumbered twice. 107 was scrapped in December 1931, 106 i 1933.

Principal Dimensions by Steve Llanso of Sweat House Media

ClassQ
Locobase ID10225
RailroadBallymena & Larne
CountryIreland
Whyte0-6-0T
Number in Class2
Road Numbers2-3 / 65-66 / 106-107
Gauge3'
Number Built2
BuilderBeyer, Peacock
Year1877
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m)10.50 / 3.20
Engine Wheelbase (ft / m)10.50 / 3.20
Ratio of driving wheelbase to overall engine wheelbase1
Overall Wheelbase (engine & tender) (ft / m)10.50 / 3.20
Axle Loading (Maximum Weight per Axle) (lbs / kg)19,040 / 8636
Weight on Drivers (lbs / kg)54,880 / 24,893
Engine Weight (lbs / kg)54,880 / 24,893
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)54,880 / 24,893
Tender Water Capacity (gals / ML)504 / 1.91
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)30 / 15
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)39 / 991
Boiler Pressure (psi / kPa)140 / 9.70
High Pressure Cylinders (dia x stroke) (in / mm)13.5" x 18" / 343x457
Tractive Effort (lbs / kg)10,010 / 4540.47
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.48
Heating Ability
Tubes (number - dia) (in / mm)132 - 1.75" / 44
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)
Firebox Area (sq ft / m2)45.55 / 4.23
Grate Area (sq ft / m2) 9.12 / 0.85
Evaporative Heating Surface (sq ft / m2)471 / 43.77
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)471 / 43.77
Evaporative Heating Surface/Cylinder Volume157.94
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1277
Same as above plus superheater percentage1277
Same as above but substitute firebox area for grate area6377
Power L12132
Power MT256.94

All material Copyright © SteamLocomotive.com
Wes Barris