Data from 1891 edition of Matthais Forney's Catechism of the Locomotive, pp. 134-135. See also DeGolyer, Volume 12, p. 70. Works numbers were 7365-7368 in June 1884.
Connelly's list (supplied by Allen Stanley) shows that the Saladillo and three other engines - Vipos 77, Tala 78, and Yatasto 79 - were produced in June 1884 as a batch. It was a small wood-burner, but it had a full "cow-catcher", out-of-scale oil headlamp, and a straight stack.
Yatasto went directly to the FC Central Norte; the other three first went to the Central de Cordoba, then eventually to the Central Norte.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | Saladillo |
Locobase ID | 8427 |
Railroad | Cordoba y Tucuman |
Country | Argentina |
Whyte | 0-4-2T |
Number in Class | 4 |
Road Numbers | 76-79 |
Gauge | Metre |
Number Built | 4 |
Builder | Burnham, Parry, Williams & Co |
Year | 1884 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 4.50 / 1.37 |
Engine Wheelbase (ft / m) | 10 / 3.05 |
Ratio of driving wheelbase to overall engine wheelbase | 0.45 |
Overall Wheelbase (engine & tender) (ft / m) | 10 / 3.05 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 28,500 / 12,927 |
Engine Weight (lbs / kg) | 36,840 / 16,710 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 450 / 1.70 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 24 / 12 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 37 / 940 |
Boiler Pressure (psi / kPa) | 150 / 1030 |
High Pressure Cylinders (dia x stroke) (in / mm) | 10" x 16" / 254x406 |
Tractive Effort (lbs / kg) | 5514 / 2501.11 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.17 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 97 - 1.5" / 38 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 8.02 / 2.44 |
Firebox Area (sq ft / m2) | 33 / 3.07 |
Grate Area (sq ft / m2) | 7 / 0.65 |
Evaporative Heating Surface (sq ft / m2) | 333 / 30.95 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 333 / 30.95 |
Evaporative Heating Surface/Cylinder Volume | 228.95 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1050 |
Same as above plus superheater percentage | 1050 |
Same as above but substitute firebox area for grate area | 4950 |
Power L1 | 3167 |
Power MT | 489.97 |