Data provided by Carlos Alberto Fernandez Priotti in Bryan Attewell ([] Steam Locomotive simulator program (April 2000) and SACM diagram UG Type 178 from Elsassische Maschinenbau AG from locomotive book supplied by Dany Machi up at [] as
Diagrammes des machines SACM construites a GRAFENSTADEN (October 2007).
Powerful Consolidations that were simpled from their original layout in which they were the only four-cylinder de Glehn compounds ever to run on Argentine rails. The SACM diagram shows that fire-side diameters for the tubes and flues were 45 and 128 mm, respectively.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 111 |
Locobase ID | 3737 |
Railroad | FC Rosario a Puerto Belgrano (FCRPB) |
Country | Argentina |
Whyte | 2-8-0 |
Number in Class | 5 |
Road Numbers | 111-115 |
Gauge | 5'6" |
Number Built | 5 |
Builder | SACM |
Year | 1929 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 16.40 / 5 |
Engine Wheelbase (ft / m) | 24.28 / 7.40 |
Ratio of driving wheelbase to overall engine wheelbase | 0.68 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 146,387 / 66,400 |
Engine Weight (lbs / kg) | 165,787 / 75,200 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 4409 / 16.70 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 8.80 / 8 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 61 / 30.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 55.10 / 1400 |
Boiler Pressure (psi / kPa) | 216.10 / 1490 |
High Pressure Cylinders (dia x stroke) (in / mm) | 23.62" x 25.59" / 600x650 |
Tractive Effort (lbs / kg) | 47,594 / 21588.30 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.08 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 154 - 1.969" / 50 |
Flues (number - dia) (in / mm) | 28 - 5.236" / 133 |
Flue/Tube length (ft / m) | 13.12 / 4 |
Firebox Area (sq ft / m2) | 167.92 / 15.60 |
Grate Area (sq ft / m2) | 34.55 / 3.21 |
Evaporative Heating Surface (sq ft / m2) | 1755 / 163.06 |
Superheating Surface (sq ft / m2) | 587 / 54.55 |
Combined Heating Surface (sq ft / m2) | 2342 / 217.61 |
Evaporative Heating Surface/Cylinder Volume | 135.23 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 7466 |
Same as above plus superheater percentage | 9333 |
Same as above but substitute firebox area for grate area | 45,359 |
Power L1 | 12,046 |
Power MT | 725.66 |