See [] (original link); later link "SKGLB 12" on the Club 760 website at [], last accessed 2 July 2024. Works numbers were 2324-2325, 2340-2342 in 1890, 2511 in 1891. 2751-2752 in 1892, 2821-2822 in 1893, 3034 in 1894, 5513 in 1906.
Little tank engine that worked the narrow-gauge SKGLB until it closed, hauling freight from Bad Ischi to the Salzburg/Itzling depot. From 1958 to 1973 it operated on the Feistitzalbahn section of the StLB. Club 760 bought her in 1975 and sometime later she was added to the Frojach Museum's stud.
Boiler pressure is an estimate based on engines supplied to the Mariazellerbahn by Krauss Linz.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 1 |
| Locobase ID | 4829 |
| Railroad | Salzkammergut-Lokalbahn /StLB |
| Country | Austria |
| Whyte | 0-6-2T |
| Number in Class | 12 |
| Road Numbers | S 1-S 12 |
| Gauge | 76 cm |
| Number Built | 12 |
| Builder | Krauss |
| Year | 1890 |
| Valve Gear | Walschaert |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | |
| Engine Wheelbase (ft / m) | |
| Ratio of driving wheelbase to overall engine wheelbase | |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | |
| Engine Weight (lbs / kg) | 50,926 / 23,100 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 739 / 2.80 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.40 / 1 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 31.50 / 800 |
| Boiler Pressure (psi / kPa) | 188.50 / 1300 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 11.42" x 15.75" / 290x400 |
| Tractive Effort (lbs / kg) | 10,448 / 4739.14 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | |
| Firebox Area (sq ft / m2) | |
| Grate Area (sq ft / m2) | 8.61 / 0.80 |
| Evaporative Heating Surface (sq ft / m2) | 541 / 50.30 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 541 / 50.30 |
| Evaporative Heating Surface/Cylinder Volume | 289.74 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1623 |
| Same as above plus superheater percentage | 1623 |
| Same as above but substitute firebox area for grate area | |
| Power L1 | |
| Power MT | |