Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 63, p. 243 Works number was 52196 in August 1919. See Locobase 12303 for a short history of railways in Barbados.
This engine repeated the design in the 1898 Mikado tanks shown in 12303, but had three fewer tubes. Its environment included 30 and 45 lb/yard (15 and 22.5 kg/metre) rails, grades of better than 3%, and tight curve radii of 150 feet (45.7 metres).
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 3 |
Locobase ID | 14391 |
Railroad | Barbados Government |
Country | Barbados |
Whyte | 2-8-2T |
Number in Class | 1 |
Road Numbers | 3 |
Gauge | 2'6" |
Number Built | 1 |
Builder | Baldwin |
Year | 1919 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 8.67 / 2.64 |
Engine Wheelbase (ft / m) | 21.33 / 6.50 |
Ratio of driving wheelbase to overall engine wheelbase | 0.41 |
Overall Wheelbase (engine & tender) (ft / m) | 21.33 / 6.50 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 49,500 / 22,453 |
Engine Weight (lbs / kg) | 67,500 / 30,618 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 1250 / 4.73 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 800 / 3028 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 21 / 10.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 30 / 762 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 13" x 16" / 330x406 |
Tractive Effort (lbs / kg) | 12,258 / 5560.14 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.04 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 93 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.75 / 3.58 |
Firebox Area (sq ft / m2) | 48.20 / 4.48 |
Grate Area (sq ft / m2) | 10 / 0.93 |
Evaporative Heating Surface (sq ft / m2) | 543 / 50.46 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 543 / 50.46 |
Evaporative Heating Surface/Cylinder Volume | 220.91 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1600 |
Same as above plus superheater percentage | 1600 |
Same as above but substitute firebox area for grate area | 7712 |
Power L1 | 2552 |
Power MT | 454.64 |