Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 66, pp. 336+. Works number was 52230 in August 1919.
Tiny wood-burning tank was identical to the one shipped a few months later to the Agricola (Locobase 15134) except that it had rectangular side tanks. It was sold to the Herdeiros de Arthur Siqueira Cavalcanti for use on their sugar plantation just south of Recife.
The buyers were the heirs to Arthur Siqueira, who died in 1918 at age 54. He must have taught them well because the family ran the mill from 1918 to 1965.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 15168 |
Railroad | Usina Pedroza |
Country | Brazil |
Whyte | 0-6-0T |
Number in Class | 1 |
Road Numbers | |
Gauge | Metre |
Number Built | 1 |
Builder | Baldwin |
Year | 1919 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 6.25 / 1.90 |
Engine Wheelbase (ft / m) | 6.25 / 1.90 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 6.25 / 1.90 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 26,000 / 11,793 |
Engine Weight (lbs / kg) | 26,000 / 11,793 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 26,000 / 11,793 |
Tender Water Capacity (gals / ML) | 250 / 0.95 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 14 / 7 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 28 / 711 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 9" x 14" / 229x356 |
Tractive Effort (lbs / kg) | 5508 / 2498.39 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.72 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 56 - 1.5" / 38 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 6.88 / 2.10 |
Firebox Area (sq ft / m2) | 28 / 2.60 |
Grate Area (sq ft / m2) | 7.40 / 0.69 |
Evaporative Heating Surface (sq ft / m2) | 179 / 16.63 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 179 / 16.63 |
Evaporative Heating Surface/Cylinder Volume | 173.65 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1184 |
Same as above plus superheater percentage | 1184 |
Same as above but substitute firebox area for grate area | 4480 |
Power L1 | 2311 |
Power MT | 587.87 |