Data from DeGolyer, Vol 79, pp. 289+. Works number was 60696 in December 1928.
This factory installation in Campos do Goytacazes in Rio de Janeiro state manufactured basic chemicals. Asmall wood-burning Mogul suited them for switching duties.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | Wanda |
Locobase ID | 15451 |
Railroad | Usina do Outeiro |
Country | Brazil |
Whyte | 2-6-0 |
Number in Class | 1 |
Road Numbers | |
Gauge | Metre |
Number Built | 1 |
Builder | Baldwin |
Year | 1928 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 8 / 2.44 |
Engine Wheelbase (ft / m) | 13.83 / 4.22 |
Ratio of driving wheelbase to overall engine wheelbase | 0.58 |
Overall Wheelbase (engine & tender) (ft / m) | 33.52 / 10.22 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 36,000 / 16,329 |
Engine Weight (lbs / kg) | 41,000 / 18,597 |
Tender Loaded Weight (lbs / kg) | 23,500 / 10,659 |
Total Engine and Tender Weight (lbs / kg) | 64,500 / 29,256 |
Tender Water Capacity (gals / ML) | 1100 / 4.17 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 20 / 10 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 33 / 838 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 11" x 16" / 279x406 |
Tractive Effort (lbs / kg) | 8976 / 4071.45 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.01 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 80 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11 / 3.35 |
Firebox Area (sq ft / m2) | 37 / 3.44 |
Grate Area (sq ft / m2) | 7.60 / 0.71 |
Evaporative Heating Surface (sq ft / m2) | 437 / 40.60 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 437 / 40.60 |
Evaporative Heating Surface/Cylinder Volume | 248.31 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1368 |
Same as above plus superheater percentage | 1368 |
Same as above but substitute firebox area for grate area | 6660 |
Power L1 | 3499 |
Power MT | 642.83 |