Class 65 (Locobase 13868)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 39, p 241. Works numbers were 37515-37518 in February 1912.

The RSM was a government-subsidized railway that resulted from the merger of two smaller railways in the state of Minas Gerais -- Estrada de Ferro Minas e Rio and Viatpo FTrrea Sapucaf -- in 1910. The quartet of wood-burning Consolidations responded to a specfication that described a maximum grade of 3% (158.4 ft/mile, to be exact) and curves as tight as 80 metres (262 ft) in radius.

Principal Dimensions by Steve Llanso of Middle Run Media
Class65
Locobase ID13868
RailroadFederaes Brazileiras Rede Sul Mineira (RSM)
CountryBrazil
Whyte2-8-0
Number in Class4
Road Numbers65-68
GaugeMetre
Number Built4
BuilderBaldwin
Year1912
Valve GearWalschaert
Locomotive Length and Weight
Driver Wheelbase (ft / m)10.67 / 3.25
Engine Wheelbase (ft / m)17 / 5.18
Ratio of driving wheelbase to overall engine wheelbase 0.63
Overall Wheelbase (engine & tender) (ft / m)42.52 / 11.31
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)74,000 / 32,659
Engine Weight (lbs / kg)83,000 / 36,287
Tender Loaded Weight (lbs / kg)50,000 / 21,772
Total Engine and Tender Weight (lbs / kg)133,000 / 58,059
Tender Water Capacity (gals / ML)2500 / 9.09
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)31 / 15.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)38 / 965
Boiler Pressure (psi / kPa)180 / 1240
High Pressure Cylinders (dia x stroke) (in / mm)15" x 20" / 381x508
Tractive Effort (lbs / kg)18,118 / 8218.20
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.08
Heating Ability
Tubes (number - dia) (in / mm)138 - 2" / 51
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)14.50 / 4.42
Firebox Area (sq ft / m2)79 / 7.34
Grate Area (sq ft / m2)22.10 / 2.05
Evaporative Heating Surface (sq ft / m2)1121 / 104.14
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)1121 / 104.14
Evaporative Heating Surface/Cylinder Volume274.04
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation3978
Same as above plus superheater percentage3978
Same as above but substitute firebox area for grate area14,220
Power L14225
Power MT503.49