Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University,Vol 78, pp. 262+. Works numbers were 58341-58342 in April 1925.
See Locobase 15397 for a description of this design. These and two others shown in Locobse 15398 were built as part of a large order of locomotives for the Sao Paulo Rio Grande.
Locobase has found little about the owners and knows only that the railway had maximum grades of 3% and relatively gentle curve radii of 80 metres. They later served the Mogyana.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | unknown |
| Locobase ID | 15396 |
| Railroad | J O Esteves |
| Country | Brazil |
| Whyte | 2-8-2 |
| Number in Class | 2 |
| Road Numbers | |
| Gauge | Metre |
| Number Built | 2 |
| Builder | Baldwin |
| Year | 1925 |
| Valve Gear | Walschaert |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 11 / 3.35 |
| Engine Wheelbase (ft / m) | 26.42 / 8.05 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.42 |
| Overall Wheelbase (engine & tender) (ft / m) | 50.50 / 15.39 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | 21,000 / 9525 |
| Weight on Drivers (lbs / kg) | 79,500 / 36,061 |
| Engine Weight (lbs / kg) | 110,500 / 50,122 |
| Tender Loaded Weight (lbs / kg) | 58,500 / 26,535 |
| Total Engine and Tender Weight (lbs / kg) | 169,000 / 76,657 |
| Tender Water Capacity (gals / ML) | 2600 / 9.85 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5.50 / 5 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 33 / 16.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 40 / 1016 |
| Boiler Pressure (psi / kPa) | 180 / 1240 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 16" x 20" / 406x508 |
| Tractive Effort (lbs / kg) | 19,584 / 8883.16 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.06 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 100 - 2" / 51 |
| Flues (number - dia) (in / mm) | 16 - 5.375" / 137 |
| Flue/Tube length (ft / m) | 13 / 3.96 |
| Firebox Area (sq ft / m2) | 152 / 14.12 |
| Grate Area (sq ft / m2) | 38.20 / 3.55 |
| Evaporative Heating Surface (sq ft / m2) | 1120 / 104.05 |
| Superheating Surface (sq ft / m2) | 277 / 25.73 |
| Combined Heating Surface (sq ft / m2) | 1397 / 129.78 |
| Evaporative Heating Surface/Cylinder Volume | 240.64 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 6876 |
| Same as above plus superheater percentage | 8251 |
| Same as above but substitute firebox area for grate area | 32,832 |
| Power L1 | 11,275 |
| Power MT | 1250.67 |