Data from catalogue illustration reprinted on narrowmind.railfan.net, supplemented by DeGolyer, Vol 79, pp. 238+. Works numbers were 61034-61036 in September 1929.
The photo shows a low-drivered, wood-burning cabbage-stack Mikado headed to a line that had 2 1/2% grades and curves with radii of 250 feet (76.2 metres) or 23 degrees. Steam was admitted to the cylinders through 8" (203 mm) piston valves. A note in the specifications states that the bottom of fire box was to be "rectilineal, so as to avoid angles in which impure properties of water accumulate."
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 310 |
Locobase ID | 5034 |
Railroad | Rede de Viacao Cearense |
Country | Brazil |
Whyte | 2-8-2 |
Number in Class | 3 |
Road Numbers | 310-312 |
Gauge | Metre |
Number Built | 3 |
Builder | Baldwin |
Year | 1929 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 11 / 3.35 |
Engine Wheelbase (ft / m) | 24.17 / 7.37 |
Ratio of driving wheelbase to overall engine wheelbase | 0.46 |
Overall Wheelbase (engine & tender) (ft / m) | 49.96 / 15.23 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 88,000 / 39,916 |
Engine Weight (lbs / kg) | 118,900 / 53,932 |
Tender Loaded Weight (lbs / kg) | 60,000 / 27,216 |
Total Engine and Tender Weight (lbs / kg) | 178,900 / 81,148 |
Tender Water Capacity (gals / ML) | 3000 / 11.36 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 37 / 18.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 42 / 1067 |
Boiler Pressure (psi / kPa) | 174 / 1200 |
High Pressure Cylinders (dia x stroke) (in / mm) | 17" x 22" / 432x559 |
Tractive Effort (lbs / kg) | 22,389 / 10155.49 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.93 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 222 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 15.50 / 4.72 |
Firebox Area (sq ft / m2) | 118 / 10.96 |
Grate Area (sq ft / m2) | 29.20 / 2.71 |
Evaporative Heating Surface (sq ft / m2) | 1910 / 177.44 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1910 / 177.44 |
Evaporative Heating Surface/Cylinder Volume | 330.47 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5081 |
Same as above plus superheater percentage | 5081 |
Same as above but substitute firebox area for grate area | 20,532 |
Power L1 | 5269 |
Power MT | 528.01 |