Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 39, pp. 233. Works numbers were 36312-36313 in March 1911and 39010-39013 in January 1913.
The first Baldwin product for the E de F de Marica was a little six-wheeler shown in Locobase 13865. It was immediately followed by the 2 and 3, which were Ten-wheelers that had the same number of tubes of greater length. That was the template for the next set, which were produced almost 2 years later.
This class was later renumbered by the Central do Brasil out of sequence as follows: 1047, 1046, 1049-1050, 1045, 1048.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 2 |
Locobase ID | 13864 |
Railroad | Marica |
Country | Brazil |
Whyte | 4-6-0 |
Number in Class | 2 |
Road Numbers | 2-7 /1045+ |
Gauge | Metre |
Number Built | 2 |
Builder | Baldwin |
Year | 1911 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 10 / 3.05 |
Engine Wheelbase (ft / m) | 19.33 / 5.89 |
Ratio of driving wheelbase to overall engine wheelbase | 0.52 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 63,000 / 28,576 |
Engine Weight (lbs / kg) | 77,500 / 35,153 |
Tender Loaded Weight (lbs / kg) | 52,000 / 23,587 |
Total Engine and Tender Weight (lbs / kg) | 129,500 / 58,740 |
Tender Water Capacity (gals / ML) | 2600 / 9.85 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 4.70 / 4 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 35 / 17.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 45 / 1143 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 16" x 20" / 406x508 |
Tractive Effort (lbs / kg) | 15,474 / 7018.90 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.07 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 132 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.79 / 3.59 |
Firebox Area (sq ft / m2) | 90 / 8.36 |
Grate Area (sq ft / m2) | 15 / 1.39 |
Evaporative Heating Surface (sq ft / m2) | 899 / 83.52 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 899 / 83.52 |
Evaporative Heating Surface/Cylinder Volume | 193.16 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2400 |
Same as above plus superheater percentage | 2400 |
Same as above but substitute firebox area for grate area | 14,400 |
Power L1 | 3478 |
Power MT | 365.13 |