Data from JP Crozet's Franco-Ethiopian Railway site, [], last accessed on 21 February 2009. (Thanks to Teemu Koivumaki for his 14 April 2023 email supplying a wealth of detail on the class's provenance.) Works numbers were 1274 in 1915 and
Teemu Koivumaki wrote Locobase "Originally. this type [was] built [for] the Madrid a Aragon 101-106 in 1915, but never delivered and [were] stored in the works of Haine st Pierre." They lingered on the fast track for years before new buyers apeared. According to Koivumaki, Four of of the six were sold to Brazil with three heading passenger service on the RSM..
Straight-back ("Crampton") boiler with Kylchap stack and nozzle in the smokebox.
Another was sold to Ethiopia (Locobase 9974).
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 260 |
Locobase ID | 21136 |
Railroad | EF de Sul Miniera |
Country | Brazil |
Whyte | 4-6-2 |
Number in Class | 3 |
Road Numbers | 260-262 |
Gauge | Metre |
Number Built | 3 |
Builder | FUF Haine Saint-Pierre |
Year | 1922 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 8.86 / 2.70 |
Engine Wheelbase (ft / m) | 25.59 / 7.80 |
Ratio of driving wheelbase to overall engine wheelbase | 0.35 |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 66,139 / 30,000 |
Engine Weight (lbs / kg) | 105,822 / 48,000 |
Tender Loaded Weight (lbs / kg) | 72,973 / 33,100 |
Total Engine and Tender Weight (lbs / kg) | 178,795 / 81,100 |
Tender Water Capacity (gals / ML) | 3168 / 12 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 4.40 / 4 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 37 / 18.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 49.20 / 1250 |
Boiler Pressure (psi / kPa) | 184.20 / 1270 |
High Pressure Cylinders (dia x stroke) (in / mm) | 15.75" x 22.05" / 400x560 |
Tractive Effort (lbs / kg) | 17,407 / 7895.69 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.80 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 97 - 1.969" / 50 |
Flues (number - dia) (in / mm) | 15 - 5" / 127 |
Flue/Tube length (ft / m) | 13.12 / 4 |
Firebox Area (sq ft / m2) | 107.60 / 10 |
Grate Area (sq ft / m2) | 26.90 / 2.50 |
Evaporative Heating Surface (sq ft / m2) | 1308 / 121.52 |
Superheating Surface (sq ft / m2) | 323 / 30.01 |
Combined Heating Surface (sq ft / m2) | 1631 / 151.53 |
Evaporative Heating Surface/Cylinder Volume | 263.06 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4955 |
Same as above plus superheater percentage | 5946 |
Same as above but substitute firebox area for grate area | 23,784 |
Power L1 | 14,439 |
Power MT | 1443.89 |