Data from "Vulcan Iron Works Germain y Sierra Order Data and Photos" supplied in April 2021 by Allen Stanley from his extensive Rail Data Exchange collection; and "Vulcan Iron Works negatives 1971.210" finding aid downloaded from the Hagley Museum website at [], last accessed 25 April, 2021; and Martin Coombs, "0-6-0ST d/w 30", cyls. 11"x16", built by Vulcan Iron Works in 1909", Chilean steam locomotives lists, Part 3 Metre-Gauge locos (October 2020), p. 49 -available at [], last accessed 25 April 2021. Vulcan Iron WorksWorks numbers were 1414-1415 in 1909.
Unfortunately, the Vulcan specification did not include heating surface areas or grate area. Locobase estimated the grate area, but is willing to be corrected.
The two six-coupled saddle tanks were named "Laurita" and "Olguita".
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | Laurita |
Locobase ID | 20879 |
Railroad | Germain y Sierra, contractors |
Country | Chile |
Whyte | 0-6-0T |
Number in Class | 2 |
Road Numbers | 1-2 |
Gauge | Metre |
Number Built | 2 |
Builder | Vulcan Iron Works |
Year | 1909 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 6.50 / 1.98 |
Engine Wheelbase (ft / m) | 6.50 / 1.98 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 6.50 / 1.98 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 46,000 / 20,865 |
Engine Weight (lbs / kg) | 46,000 / 20,865 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 46,000 / 20,865 |
Tender Water Capacity (gals / ML) | 800 / 3.03 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.75 / 0.70 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 26 / 13 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 30 / 762 |
Boiler Pressure (psi / kPa) | 165 / 1140 |
High Pressure Cylinders (dia x stroke) (in / mm) | 11" x 16" / 279x406 |
Tractive Effort (lbs / kg) | 9051 / 4105.47 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.08 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 82 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 10.33 / 3.15 |
Firebox Area (sq ft / m2) | |
Grate Area (sq ft / m2) | 8.60 / 0.80 |
Evaporative Heating Surface (sq ft / m2) | |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | |
Evaporative Heating Surface/Cylinder Volume | |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1419 |
Same as above plus superheater percentage | 1419 |
Same as above but substitute firebox area for grate area | |
Power L1 | |
Power MT |