Germain y Sierra, contractors 0-6-0 Locomotives in Chile


Class Details by Steve Llanso of Sweat House Media

Class Laurita (Locobase 20879)

Data from "Vulcan Iron Works Germain y Sierra Order Data and Photos" supplied in April 2021 by Allen Stanley from his extensive Rail Data Exchange collection; and "Vulcan Iron Works negatives 1971.210" finding aid downloaded from the Hagley Museum website at [link], last accessed 25 April, 2021; and Martin Coombs, "0-6-0ST d/w 30", cyls. 11"x16", built by Vulcan Iron Works in 1909", Chilean steam locomotives lists, Part 3 Metre-Gauge locos (October 2020), p. 49 -available at [link], last accessed 25 April 2021. Vulcan Iron WorksWorks numbers were 1414-1415 in 1909.

Unfortunately, the Vulcan specification did not include heating surface areas or grate area. Locobase estimated the grate area, but is willing to be corrected.

The two six-coupled saddle tanks were named "Laurita" and "Olguita".

Principal Dimensions by Steve Llanso of Middle Run Media
ClassLaurita
Locobase ID20879
RailroadGermain y Sierra, contractors
CountryChile
Whyte0-6-0T
Number in Class2
Road Numbers1-2
GaugeMetre
Number Built2
BuilderVulcan Iron Works
Year1909
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 6.50 / 1.98
Engine Wheelbase (ft / m) 6.50 / 1.98
Ratio of driving wheelbase to overall engine wheelbase1
Overall Wheelbase (engine & tender) (ft / m) 6.50 / 1.98
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)46,000 / 20,865
Engine Weight (lbs / kg)46,000 / 20,865
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)46,000 / 20,865
Tender Water Capacity (gals / ML)800 / 3.03
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 0.75 / 0.70
Minimum weight of rail (calculated) (lb/yd / kg/m)26 / 13
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)30 / 762
Boiler Pressure (psi / kPa)165 / 1140
High Pressure Cylinders (dia x stroke) (in / mm)11" x 16" / 279x406
Tractive Effort (lbs / kg)9051 / 4105.47
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.08
Heating Ability
Tubes (number - dia) (in / mm)82 - 1.75" / 44
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)10.33 / 3.15
Firebox Area (sq ft / m2)
Grate Area (sq ft / m2) 8.60 / 0.80
Evaporative Heating Surface (sq ft / m2)
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)
Evaporative Heating Surface/Cylinder Volume
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1419
Same as above plus superheater percentage1419
Same as above but substitute firebox area for grate area
Power L1
Power MT