FC de Mineral de Chiquicamata 2-6-2 Locomotives in Chile


Class Details by Steve Llanso of Sweat House Media

Class 2 (Locobase 14521)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Vol 54, p. 377. Works number was 45544 in May 1917.

Baldwin supplied a Prairie tank design that was essentially identical to the US shortline Mocanaqua & Eastern engine delivered in 1905 (Locobase 12865) and even ran on the same gauge. Conversion to oil-burning led to a note in the specs that the firebox was to have "suitable openings in fire pan to insure ample steaming capacity at 10,000 feet (3,048 m) altitude." It also had to get around 15 degrees (radii of 383 feet/117 metres).

Chiquicamata was located in the Atacama Desert fifteen miles (24 km) north of Calama and about 231 km (143 miles) northeast of the port of Antofagasta.

Principal Dimensions by Steve Llanso of Middle Run Media
Class2
Locobase ID14521
RailroadFC de Mineral de Chiquicamata
CountryChile
Whyte2-6-2T
Number in Class1
Road Numbers2
GaugeStd
Number Built1
BuilderBaldwin
Year1917
Valve GearWalschaert
Locomotive Length and Weight
Driver Wheelbase (ft / m)10 / 3.05
Engine Wheelbase (ft / m)25.25 / 7.70
Ratio of driving wheelbase to overall engine wheelbase 0.40
Overall Wheelbase (engine & tender) (ft / m)25.25 / 7.70
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)114,000 / 51,710
Engine Weight (lbs / kg)164,000 / 74,389
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)164,000 / 74,389
Tender Water Capacity (gals / ML)1900 / 7.20
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)800 / 3028
Minimum weight of rail (calculated) (lb/yd / kg/m)63 / 31.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)46 / 1168
Boiler Pressure (psi / kPa)180 / 1240
High Pressure Cylinders (dia x stroke) (in / mm)18" x 24" / 457x610
Tractive Effort (lbs / kg)25,864 / 11731.73
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.41
Heating Ability
Tubes (number - dia) (in / mm)260 - 2" / 51
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)10.25 / 3.12
Firebox Area (sq ft / m2)134 / 12.45
Grate Area (sq ft / m2)49.50 / 4.60
Evaporative Heating Surface (sq ft / m2)1518 / 141.08
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)1518 / 141.08
Evaporative Heating Surface/Cylinder Volume214.75
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation8910
Same as above plus superheater percentage8910
Same as above but substitute firebox area for grate area24,120
Power L14272
Power MT247.85

All material Copyright © SteamLocomotive.com
Wes Barris