Dah Sing Cotton Spinning and Weaving Company 0-4-0 Locomotives in China


Class Details by Steve Llanso of Sweat House Media

Class unknown (Locobase 14620)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 60, pp. 144. Works number was 53176 in April 1920.

Bought for this Chinese customer through Anderson Meyer & Company. While not in the top rank, Dah Sung (of Nantung) was one of the larger cotton mills in the Shanghai area at the time they bought this little tank.

See Locobase 14621 for the larger six-coupled saddle tank that was delivered in 1921.

Principal Dimensions by Steve Llanso of Middle Run Media
Classunknown
Locobase ID14620
RailroadDah Sing Cotton Spinning and Weaving Company
CountryChina
Whyte0-4-0ST
Number in Class1
Road Numbers
Gauge60 cm
Number Built1
BuilderBaldwin
Year1920
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 3.33 / 1.01
Engine Wheelbase (ft / m) 3.33 / 1.01
Ratio of driving wheelbase to overall engine wheelbase1
Overall Wheelbase (engine & tender) (ft / m) 3.33 / 1.01
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)13,500 / 6124
Engine Weight (lbs / kg)13,500 / 6124
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)100 / 0.38
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)11 / 5.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)20 / 508
Boiler Pressure (psi / kPa)160 / 1100
High Pressure Cylinders (dia x stroke) (in / mm)6" x 10" / 152x254
Tractive Effort (lbs / kg)2448 / 1110.40
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.51
Heating Ability
Tubes (number - dia) (in / mm)46 - 1.5" / 38
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)6 / 1.83
Firebox Area (sq ft / m2)16 / 1.49
Grate Area (sq ft / m2) 2.90 / 0.27
Evaporative Heating Surface (sq ft / m2)123 / 11.43
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)123 / 11.43
Evaporative Heating Surface/Cylinder Volume375.86
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation464
Same as above plus superheater percentage464
Same as above but substitute firebox area for grate area2560
Power L13308
Power MT1080.43

All material Copyright © SteamLocomotive.com
Wes Barris