Data from "Contractors' Tank Locomotive, Shanghai-Nanking Ry", The Locomotive Magazine, (15 June 1906), p. 101.
Sir J Wolfe Barry of Morrison & Barry had final say on the construction of these two saddle-tankers as his firm built the S N R.
The locomotive wasn't particularly big nor replete with innovation, but it didn't need more than it had to support construction work.
NB: Tube length is an estimate based on the calculation of tube surface area by subtracting reported firebox heating surface from reported total evaporative heating surface.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | unknown |
| Locobase ID | 10563 |
| Railroad | Contractors' Tank |
| Country | China |
| Whyte | 0-6-0ST |
| Number in Class | 2 |
| Road Numbers | |
| Gauge | Std |
| Number Built | 2 |
| Builder | WG Bagnall |
| Year | 1906 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 11 / 3.35 |
| Engine Wheelbase (ft / m) | 11 / 3.35 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 11 / 3.35 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 72,800 / 33,022 |
| Engine Weight (lbs / kg) | 72,800 / 33,022 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 865 / 3.28 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 40 / 20 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 43 / 1092 |
| Boiler Pressure (psi / kPa) | 160 / 1100 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 15" x 20" / 381x508 |
| Tractive Effort (lbs / kg) | 14,233 / 6455.99 |
| Booster (lbs) | 2 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.11 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 152 - 1.75" / 44 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 9.42 / 2.90 |
| Firebox Area (sq ft / m2) | 68.25 / 6.34 |
| Grate Area (sq ft / m2) | 14 / 1.30 |
| Evaporative Heating Surface (sq ft / m2) | 722 / 67.10 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 722 / 67.10 |
| Evaporative Heating Surface/Cylinder Volume | 176.50 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2240 |
| Same as above plus superheater percentage | 2240 |
| Same as above but substitute firebox area for grate area | 10,920 |
| Power L1 | 2980 |
| Power MT | 270.73 |