Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 64, p. 112+. Works numbers were 52336 in September 1919 and 54253 in January 1921
Small plantation six-coupled for a Central located in Oriente Province at La Demajagua (near Manzanillo). As so often happened with a later order of what was to be a duplicate, the 4 weighed 2,500 lb (1,134 kg) more than the 3.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 3 |
| Locobase ID | 14851 |
| Railroad | Central Salvador |
| Country | Cuba |
| Whyte | 0-6-0 |
| Number in Class | 2 |
| Road Numbers | 3-4 |
| Gauge | 3' |
| Number Built | 2 |
| Builder | Baldwin |
| Year | 1919 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 8.08 / 2.46 |
| Engine Wheelbase (ft / m) | 8.08 / 2.46 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 31.62 / 9.64 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 36,000 / 16,329 |
| Engine Weight (lbs / kg) | 36,000 / 16,329 |
| Tender Loaded Weight (lbs / kg) | 27,500 / 12,474 |
| Total Engine and Tender Weight (lbs / kg) | 63,500 / 28,803 |
| Tender Water Capacity (gals / ML) | 1200 / 4.55 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 2.50 / 2 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 20 / 10 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 37 / 940 |
| Boiler Pressure (psi / kPa) | 150 / 1030 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 12" x 18" / 305x457 |
| Tractive Effort (lbs / kg) | 8932 / 4051.49 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.03 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 61 - 2" / 51 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 10.92 / 3.33 |
| Firebox Area (sq ft / m2) | 45.60 / 4.24 |
| Grate Area (sq ft / m2) | 6.83 / 0.63 |
| Evaporative Heating Surface (sq ft / m2) | 392 / 36.42 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 392 / 36.42 |
| Evaporative Heating Surface/Cylinder Volume | 166.37 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1025 |
| Same as above plus superheater percentage | 1025 |
| Same as above but substitute firebox area for grate area | 6840 |
| Power L1 | 2434 |
| Power MT | 447.17 |