Class 3 (Locobase 14851)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 64, p. 112+. Works numbers were 52336 in September 1919 and 54253 in January 1921

Small plantation six-coupled for a Central located in Oriente Province at La Demajagua (near Manzanillo). As so often happened with a later order of what was to be a duplicate, the 4 weighed 2,500 lb (1,134 kg) more than the 3.

Principal Dimensions by Steve Llanso of Middle Run Media
Class3
Locobase ID14851
RailroadCentral Salvador
CountryCuba
Whyte0-6-0
Number in Class2
Road Numbers3-4
Gauge3'
Number Built2
BuilderBaldwin
Year1919
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 8.08 / 2.46
Engine Wheelbase (ft / m) 8.08 / 2.46
Ratio of driving wheelbase to overall engine wheelbase1
Overall Wheelbase (engine & tender) (ft / m)31.62 / 9.64
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)36,000 / 16,329
Engine Weight (lbs / kg)36,000 / 16,329
Tender Loaded Weight (lbs / kg)27,500 / 12,474
Total Engine and Tender Weight (lbs / kg)63,500 / 28,803
Tender Water Capacity (gals / ML)1200 / 4.55
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 2.50 / 2
Minimum weight of rail (calculated) (lb/yd / kg/m)20 / 10
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)37 / 940
Boiler Pressure (psi / kPa)150 / 1030
High Pressure Cylinders (dia x stroke) (in / mm)12" x 18" / 305x457
Tractive Effort (lbs / kg)8932 / 4051.49
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.03
Heating Ability
Tubes (number - dia) (in / mm)61 - 2" / 51
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)10.92 / 3.33
Firebox Area (sq ft / m2)45.60 / 4.24
Grate Area (sq ft / m2) 6.83 / 0.63
Evaporative Heating Surface (sq ft / m2)392 / 36.42
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)392 / 36.42
Evaporative Heating Surface/Cylinder Volume166.37
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1025
Same as above plus superheater percentage1025
Same as above but substitute firebox area for grate area6840
Power L12434
Power MT447.17