Data from DeGolyer, Vol 64, pp. 337. Works numbers were 51202 in February 1921.
This plantation six-coupled, wood-burning saddle tank had a Radley & Hunter diamond stack, a necessity for wood-burners to reduce sparks in highly flammable surroundings such as cane fields. The fuel box held 50 cu ft (1.4 cu m).Data from Roy V Wright (ed), Figure 2175, "Foreign Steam Locomotives: Industrial, Tank", Locomotive Cyclopedia of American Practice (Tenth Edition--1938 (New York: Simmons-Boardman Publishing Corporation, 1938),, p. 976. Works numbers were 65934-65936 in September 1924.
Healthy looking six-coupled plantation tank. The valve gear supplied by the Pilliod Corp was rarely seen on forest or on the coffee or sugar plantation locomotives.
Principal Dimensions by Steve Llanso of Sweat House Media | ||
---|---|---|
Class | 23 | 71 |
Locobase ID | 14921 | 20971 |
Railroad | Manati Sugar Company | Manati Sugar Company |
Country | Cuba | Cuba |
Whyte | 0-6-0ST | 0-6-0T |
Number in Class | 1 | 3 |
Road Numbers | 23 | 71-73 |
Gauge | 3' | 85 cm |
Number Built | 1 | 3 |
Builder | Baldwin | Alco-Cooke |
Year | 1919 | 1924 |
Valve Gear | Stephenson | Baker |
Locomotive Length and Weight | ||
Driver Wheelbase (ft / m) | 8.50 / 2.59 | 8 / 2.44 |
Engine Wheelbase (ft / m) | 8.50 / 2.59 | 8 / 2.44 |
Ratio of driving wheelbase to overall engine wheelbase | 1 | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 8.50 / 2.59 | 8 / 2.44 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | ||
Weight on Drivers (lbs / kg) | 50,000 / 22,680 | 92,500 |
Engine Weight (lbs / kg) | 50,000 / 22,680 | 92,500 / 41,957 |
Tender Loaded Weight (lbs / kg) | ||
Total Engine and Tender Weight (lbs / kg) | 50,000 / 22,680 | 92,500 / 41,957 |
Tender Water Capacity (gals / ML) | 500 / 1.89 | |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | ||
Minimum weight of rail (calculated) (lb/yd / kg/m) | 28 / 14 | 51 / 25.50 |
Geometry Relating to Tractive Effort | ||
Driver Diameter (in / mm) | 37 / 940 | 42 / 1067 |
Boiler Pressure (psi / kPa) | 150 / 10.30 | 180 / 12.40 |
High Pressure Cylinders (dia x stroke) (in / mm) | 13" x 18" / 330x457 | 15" x 22" / 330x559 |
Tractive Effort (lbs / kg) | 10,483 / 4755.01 | 18,032 / 8179.19 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.77 | 5.13 |
Heating Ability | ||
Tubes (number - dia) (in / mm) | 72 - 2" / 51 | |
Flues (number - dia) (in / mm) | ||
Flue/Tube length (ft / m) | 9 / 2.74 | |
Firebox Area (sq ft / m2) | 43 / 3.99 | 69 / 6.41 |
Grate Area (sq ft / m2) | 7.70 / 0.72 | 20 / 1.86 |
Evaporative Heating Surface (sq ft / m2) | 379 / 35.21 | 1015 / 94.30 |
Superheating Surface (sq ft / m2) | ||
Combined Heating Surface (sq ft / m2) | 379 / 35.21 | 1015 / 94.30 |
Evaporative Heating Surface/Cylinder Volume | 137.06 | 225.57 |
Computations Relating to Power Output (More Information) | ||
Robert LeMassena's Power Computation | 1155 | 3600 |
Same as above plus superheater percentage | 1155 | 3600 |
Same as above but substitute firebox area for grate area | 6450 | 12,420 |
Power L1 | 1987 | 3808 |
Power MT | 262.83 | 272.28 |