Central San Ramon 0-6-2 Locomotives in Cuba


Class Details by Steve Llanso of Sweat House Media

Class 4 (Locobase 14860)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Vol 64, p. 151. Works number was 56639 in June 1923.

If one thinks about turning around a tiny plantation Mogul and putting a saddle tank, this radial tank might result. Such engines needed to show a little self-sufficiency, or so this note suggests: "One of the three cab lamps to have long wire for use with a trouble light, and to reach around the loco." The 4 rolled on 40 lb/yard (20 kg/metre) rail around curves with radii of 150 feet (45.7 m).

Principal Dimensions by Steve Llanso of Sweat House Media

Class4
Locobase ID14860
RailroadCentral San Ramon
CountryCuba
Whyte0-6-2ST
Number in Class1
Road Numbers4
Gauge2' 10
Number Built1
BuilderBaldwin
Year1923
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 6.83 / 2.08
Engine Wheelbase (ft / m)13.08 / 3.99
Ratio of driving wheelbase to overall engine wheelbase 0.52
Overall Wheelbase (engine & tender) (ft / m)13.08 / 3.99
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)29,500 / 13,381
Engine Weight (lbs / kg)35,500 / 16,103
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)35,500 / 16,103
Tender Water Capacity (gals / ML)500 / 1.89
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 0.60 / 1
Minimum weight of rail (calculated) (lb/yd / kg/m)16 / 8
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)33 / 838
Boiler Pressure (psi / kPa)170 / 11.70
High Pressure Cylinders (dia x stroke) (in / mm)9" x 16" / 229x406
Tractive Effort (lbs / kg)5675 / 2574.14
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.20
Heating Ability
Tubes (number - dia) (in / mm)59 - 1.75" / 44
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m) 9.50 / 2.90
Firebox Area (sq ft / m2)29 / 2.69
Grate Area (sq ft / m2) 7.16 / 0.67
Evaporative Heating Surface (sq ft / m2)284 / 26.38
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)284 / 26.38
Evaporative Heating Surface/Cylinder Volume241.07
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1217
Same as above plus superheater percentage1217
Same as above but substitute firebox area for grate area4930
Power L13405
Power MT763.40

All material Copyright © SteamLocomotive.com