Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Vol 78, p. 55. Works number was 58438 in May 1925.
This oil-burning plantation Six-wheeler may have had limited power, but was paid for and lasted for decades in Cuban service. The specification called for the 1 to scale 1% grades and get around 20 degree curves.
It was later sold to the Central Corazón de Jes+s in Cifuentes in Las Villas Province. After the 1959 Revolucion and expropriation, the CCdJ was renamed for Mariana Grajales and the engine renumbered 1224.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 1 |
Locobase ID | 15354 |
Railroad | Central Santa Marta |
Country | Cuba |
Whyte | 2-4-0 |
Number in Class | 1 |
Road Numbers | 1 / 1224 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1925 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 7 / 2.13 |
Engine Wheelbase (ft / m) | 14.92 / 4.55 |
Ratio of driving wheelbase to overall engine wheelbase | 0.47 |
Overall Wheelbase (engine & tender) (ft / m) | 41.52 / 12.66 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 70,000 / 31,752 |
Engine Weight (lbs / kg) | 84,000 / 38,102 |
Tender Loaded Weight (lbs / kg) | 59,000 / 26,762 |
Total Engine and Tender Weight (lbs / kg) | 143,000 / 64,864 |
Tender Water Capacity (gals / ML) | 2500 / 9.47 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1200 / 4542 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 58 / 29 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 44 / 1118 |
Boiler Pressure (psi / kPa) | 170 / 1170 |
High Pressure Cylinders (dia x stroke) (in / mm) | 14" x 24" / 356x610 |
Tractive Effort (lbs / kg) | 15,448 / 7007.10 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.53 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 123 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 9 / 2.74 |
Firebox Area (sq ft / m2) | 64 / 5.95 |
Grate Area (sq ft / m2) | 16 / 1.49 |
Evaporative Heating Surface (sq ft / m2) | 638 / 59.29 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 638 / 59.29 |
Evaporative Heating Surface/Cylinder Volume | 149.20 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2720 |
Same as above plus superheater percentage | 2720 |
Same as above but substitute firebox area for grate area | 10,880 |
Power L1 | 2793 |
Power MT | 175.93 |