Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 44, p. 280, Vol 54 p. 80, Vol 64, pp. 275. See also Cesar J Ayala, American sugar kingdom: the plantation economy of the Spanish Caribbean 1898-1934 (University of North Carolina Press, 1999). Works numbers were 38408 in September 1912, 41654 in August 1914, 47289 in December 1917.
See 13630 for a description of the large New Niquero plantation owned by Cuban American Sugar Company. The company bought the same design of plantation Mogul as singles in several years.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 2 |
Locobase ID | 13631 |
Railroad | New Niquero Sugar Company |
Country | Cuba |
Whyte | 2-6-0 |
Number in Class | 2 |
Road Numbers | 2, 4, 6 |
Gauge | 3' |
Number Built | 2 |
Builder | Baldwin |
Year | 1912 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 9.67 / 2.95 |
Engine Wheelbase (ft / m) | 15.92 / 4.85 |
Ratio of driving wheelbase to overall engine wheelbase | 0.61 |
Overall Wheelbase (engine & tender) (ft / m) | 36.92 / 11.25 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 49,000 / 22,226 |
Engine Weight (lbs / kg) | 58,000 / 26,308 |
Tender Loaded Weight (lbs / kg) | 44,000 / 19,958 |
Total Engine and Tender Weight (lbs / kg) | 102,000 / 46,266 |
Tender Water Capacity (gals / ML) | 2200 / 8.33 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5 / 5 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 27 / 13.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 42 / 1067 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 14" x 18" / 356x457 |
Tractive Effort (lbs / kg) | 11,424 / 5181.85 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.29 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 153 - 1.75" / 44 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 8.62 / 2.63 |
Firebox Area (sq ft / m2) | 71 / 6.60 |
Grate Area (sq ft / m2) | 12.50 / 1.16 |
Evaporative Heating Surface (sq ft / m2) | 669 / 62.15 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 669 / 62.15 |
Evaporative Heating Surface/Cylinder Volume | 208.60 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2000 |
Same as above plus superheater percentage | 2000 |
Same as above but substitute firebox area for grate area | 11,360 |
Power L1 | 3576 |
Power MT | 482.68 |