Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 64 p. 406. Works number was 53574 and 53586 in August 1920.
West India Sugar Finance Corporation bought these two oil-burning plantation Moguls, which were delivered to Centrales Alto Cedro in Oriente Province and Santa Ana. The 102 was later sold to the Central Tinguaro. Their design had a longer than usual stroke for sugar 2-6-0s.
A "Hereafter"note dated June 1924 stipulated that all future Baldwins bought by WISFC would be delivered with Walschaert outside constant-lead radial valve gear.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 101 |
Locobase ID | 14930 |
Railroad | Santa Ana Sugar Company |
Country | Cuba |
Whyte | 2-6-0 |
Number in Class | 2 |
Road Numbers | 101-102 |
Gauge | Std |
Number Built | 2 |
Builder | Baldwin |
Year | 1920 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 13 / 3.96 |
Engine Wheelbase (ft / m) | 20.71 / 6.31 |
Ratio of driving wheelbase to overall engine wheelbase | 0.63 |
Overall Wheelbase (engine & tender) (ft / m) | 46.29 / 14.11 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 100,900 / 45,768 |
Engine Weight (lbs / kg) | 116,600 / 52,889 |
Tender Loaded Weight (lbs / kg) | 100,000 / 45,359 |
Total Engine and Tender Weight (lbs / kg) | 216,600 / 98,248 |
Tender Water Capacity (gals / ML) | 5000 / 18.94 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 2000 / 7570 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 56 / 28 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 56 / 1422 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 18" x 26" / 457x660 |
Tractive Effort (lbs / kg) | 23,016 / 10439.89 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.38 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 243 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11 / 3.35 |
Firebox Area (sq ft / m2) | 135 / 12.55 |
Grate Area (sq ft / m2) | 22.40 / 2.08 |
Evaporative Heating Surface (sq ft / m2) | 1524 / 141.64 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1524 / 141.64 |
Evaporative Heating Surface/Cylinder Volume | 199.02 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4032 |
Same as above plus superheater percentage | 4032 |
Same as above but substitute firebox area for grate area | 24,300 |
Power L1 | 4824 |
Power MT | 316.21 |