Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 32, p 302. Works number was 32990 in October 1908.
This sugar-plantation railroad was the Central San Agustin that was located at Lajas in Cienfuegos Province in the western part of Cuba.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | Central San Agustin |
| Locobase ID | 13491 |
| Railroad | Central San Agustin |
| Country | Cuba |
| Whyte | 2-6-2T |
| Number in Class | 1 |
| Road Numbers | |
| Gauge | Std |
| Number Built | 1 |
| Builder | Burnham, Williams & Co |
| Year | 1908 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 9 / 2.74 |
| Engine Wheelbase (ft / m) | 24.67 / 7.52 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.36 |
| Overall Wheelbase (engine & tender) (ft / m) | 24.67 / 7.52 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 72,000 / 32,659 |
| Engine Weight (lbs / kg) | 95,000 / 43,091 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 1600 / 6.06 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 40 / 20 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 44 / 1118 |
| Boiler Pressure (psi / kPa) | 160 / 1100 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 15" x 22" / 381x559 |
| Tractive Effort (lbs / kg) | 15,300 / 6939.97 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.71 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 104 - 2" / 51 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 13 / 3.96 |
| Firebox Area (sq ft / m2) | 67.50 / 6.27 |
| Grate Area (sq ft / m2) | 12.80 / 1.19 |
| Evaporative Heating Surface (sq ft / m2) | 771 / 71.63 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 771 / 71.63 |
| Evaporative Heating Surface/Cylinder Volume | 171.35 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2048 |
| Same as above plus superheater percentage | 2048 |
| Same as above but substitute firebox area for grate area | 10,800 |
| Power L1 | 2891 |
| Power MT | 265.56 |