Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Vol 78, p. 52. Works number was 58556 in July 1925.
This oil-burning plantation Praire had 8" (203 mm) piston valves. It went to the CSM in Ranchuelo in Las Villas Province, a mill first operated by the Casicedo Torriente family in 1849. The 1 was specified to negotiate a 11 degree curve (on a chord of 50 feet/15.24 metres), which was a calculated radius of 344 feet (104.85 metres) as well as curves of "163.8 metres (537 feet)".
After the 1959 Revolucion and expropriation, the CSM was renamed for Ifrain Alfonso and the engine renumbered 1635.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 1 |
Locobase ID | 15353 |
Railroad | Central Santa Maria |
Country | Cuba |
Whyte | 2-6-2 |
Number in Class | 1 |
Road Numbers | 1 / 1635 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1920 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 10.25 / 3.12 |
Engine Wheelbase (ft / m) | 27 / 8.23 |
Ratio of driving wheelbase to overall engine wheelbase | 0.38 |
Overall Wheelbase (engine & tender) (ft / m) | 51.33 / 15.65 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 95,000 / 43,091 |
Engine Weight (lbs / kg) | 123,000 / 55,792 |
Tender Loaded Weight (lbs / kg) | 109,000 / 49,442 |
Total Engine and Tender Weight (lbs / kg) | 232,000 / 105,234 |
Tender Water Capacity (gals / ML) | 5000 / 18.94 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 2000 / 7570 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 53 / 26.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 50 / 1270 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 18" x 24" / 457x610 |
Tractive Effort (lbs / kg) | 23,795 / 10793.24 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 3.99 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 200 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 14.75 / 4.50 |
Firebox Area (sq ft / m2) | 98 / 9.11 |
Grate Area (sq ft / m2) | 21.90 / 2.04 |
Evaporative Heating Surface (sq ft / m2) | 1634 / 151.86 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1634 / 151.86 |
Evaporative Heating Surface/Cylinder Volume | 231.16 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 3942 |
Same as above plus superheater percentage | 3942 |
Same as above but substitute firebox area for grate area | 17,640 |
Power L1 | 4507 |
Power MT | 313.78 |