Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 27, p 104. Works number was 24615 in November 1904.
The Krajewski-Pesant brokerage company bought this saddle-tank Prairie for Francisca M Duranona of the Ingenio Toledo. The specifications called for a 250-ton trailing load to be hauled up a 1 1/2% grade with a 200-metre radius.
Many years later, after the 1959 Revolucion and expropriation, the Toledo was renamed for Marcelo Salada and the
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | Silvia |
Locobase ID | 13637 |
Railroad | Central Toledo |
Country | Cuba |
Whyte | 2-6-2ST |
Number in Class | 1 |
Road Numbers | 2 |
Gauge | Std |
Number Built | 1 |
Builder | Burnham, Williams & Co |
Year | 1904 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 9 / 2.74 |
Engine Wheelbase (ft / m) | 24.67 / 7.52 |
Ratio of driving wheelbase to overall engine wheelbase | 0.36 |
Overall Wheelbase (engine & tender) (ft / m) | 24.67 / 7.52 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 68,500 / 31,071 |
Engine Weight (lbs / kg) | 89,700 / 40,687 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 89,700 / 40,687 |
Tender Water Capacity (gals / ML) | 1500 / 5.68 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 2.10 / 2 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 38 / 19 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 44 / 1118 |
Boiler Pressure (psi / kPa) | 160 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 15" x 22" / 381x559 |
Tractive Effort (lbs / kg) | 15,300 / 6939.97 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.48 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 104 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 13 / 3.96 |
Firebox Area (sq ft / m2) | 67.50 / 6.27 |
Grate Area (sq ft / m2) | 12.81 / 1.19 |
Evaporative Heating Surface (sq ft / m2) | 771 / 71.63 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 771 / 71.63 |
Evaporative Heating Surface/Cylinder Volume | 171.35 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2050 |
Same as above plus superheater percentage | 2050 |
Same as above but substitute firebox area for grate area | 10,800 |
Power L1 | 2891 |
Power MT | 279.13 |