Data from Baldwin negative 6193 as reproduced on narrowmind.railfan.net. See also DeGolyer, Volume 54, pp. 142. Works number was 44693 in December 1916.
This Prairie Mallet worked the sugar-cane plantations of Cuba. Given its size and the use of soft coal as a fuel, it likely that #18 hauled long trains of cane from the plantation to processing plants or to the docks. All four cylinders were supplied through slide valves.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 18 |
Locobase ID | 4431 |
Railroad | Manati Sugar Company |
Country | Cuba |
Whyte | 2-6-6-2 |
Number in Class | 1 |
Road Numbers | 18 |
Gauge | 3' |
Number Built | 1 |
Builder | Baldwin |
Year | 1917 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 7.83 / 2.39 |
Engine Wheelbase (ft / m) | 22.83 / 6.96 |
Ratio of driving wheelbase to overall engine wheelbase | 0.34 |
Overall Wheelbase (engine & tender) (ft / m) | 33.25 / 10.13 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 123,900 / 56,200 |
Engine Weight (lbs / kg) | 140,300 / 63,639 |
Tender Loaded Weight (lbs / kg) | 59,700 / 27,079 |
Total Engine and Tender Weight (lbs / kg) | 200,000 / 90,718 |
Tender Water Capacity (gals / ML) | 3500 / 13.26 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 6 / 6 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 34 / 17 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 41 / 1041 |
Boiler Pressure (psi / kPa) | 204.50 / 1410 |
High Pressure Cylinders (dia x stroke) (in / mm) | 14.5" x 20" / 368x508 |
Low Pressure Cylinders (dia x stroke) (in / mm) | 22" x 20" / 559x508 |
Tractive Effort (lbs / kg) | 24,857 / 11274.96 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.98 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 150 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 17 / 5.18 |
Firebox Area (sq ft / m2) | 86 / 7.99 |
Grate Area (sq ft / m2) | 23.80 / 2.21 |
Evaporative Heating Surface (sq ft / m2) | 1415 / 131.51 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1415 / 131.51 |
Evaporative Heating Surface/Cylinder Volume | 370.18 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4867 |
Same as above plus superheater percentage | 4867 |
Same as above but substitute firebox area for grate area | 17,587 |
Power L1 | 2930 |
Power MT | 312.81 |