Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 27, p 208. Works number was 25040 in January 1905.
The Cuban Planters Company ordered this little Consolidation for its plantation railroad.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | 2 |
| Locobase ID | 12759 |
| Railroad | Tacajo Cacao & Sugar Company |
| Country | Cuba |
| Whyte | 2-8-0 |
| Number in Class | 1 |
| Road Numbers | 2 |
| Gauge | 3' |
| Number Built | 1 |
| Builder | Burnham, Williams & Co |
| Year | 1905 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 11.33 / 3.45 |
| Engine Wheelbase (ft / m) | 17.83 / 5.43 |
| Ratio of driving wheelbase to overall engine wheelbase | 0.64 |
| Overall Wheelbase (engine & tender) (ft / m) | |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 59,000 / 26,762 |
| Engine Weight (lbs / kg) | 67,000 / 30,391 |
| Tender Loaded Weight (lbs / kg) | 40,000 / 18,144 |
| Total Engine and Tender Weight (lbs / kg) | 107,000 / 48,535 |
| Tender Water Capacity (gals / ML) | 2000 / 7.58 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1500 / 5678 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 25 / 12.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 36 / 914 |
| Boiler Pressure (psi / kPa) | 160 / 1100 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 14" x 18" / 356x457 |
| Tractive Effort (lbs / kg) | 13,328 / 6045.49 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.43 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | 138 - 2" / 51 |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | 10 / 3.05 |
| Firebox Area (sq ft / m2) | 84 / 7.81 |
| Grate Area (sq ft / m2) | 13.70 / 1.27 |
| Evaporative Heating Surface (sq ft / m2) | 800 / 74.35 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 800 / 74.35 |
| Evaporative Heating Surface/Cylinder Volume | 249.45 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2192 |
| Same as above plus superheater percentage | 2192 |
| Same as above but substitute firebox area for grate area | 13,440 |
| Power L1 | 3652 |
| Power MT | 545.85 |