Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 64, p. 357.. Works numbers were 52295-52296 in September 1919.
These Mikados were duplicates of the narrow-gauge plantation Consolidations procured from Baldwin earlier in the decade (Locobases 14022 and 14439). The addition of a trailing axle may have been adopted to improve bi-directional running as there was little increase in adhesive weight and no change in either boiler and firebox dimensions or in power dimensions. The 2-8-2s were delivered as oil burners (as opposed to the coal fuel used in the 2-8-0s) and the tenders were little bigger and plumbed to carry heavy Tampico oil.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 24 |
Locobase ID | 14443 |
Railroad | Manati Sugar Company |
Country | Cuba |
Whyte | 2-8-2 |
Number in Class | 2 |
Road Numbers | 24-25 |
Gauge | 3' |
Number Built | 2 |
Builder | Baldwin |
Year | 1919 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 11.50 / 3.51 |
Engine Wheelbase (ft / m) | 25 / 7.62 |
Ratio of driving wheelbase to overall engine wheelbase | 0.46 |
Overall Wheelbase (engine & tender) (ft / m) | 46.94 / 14.31 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 82,000 / 37,195 |
Engine Weight (lbs / kg) | 100,000 / 45,359 |
Tender Loaded Weight (lbs / kg) | 65,400 / 29,665 |
Total Engine and Tender Weight (lbs / kg) | 165,400 / 75,024 |
Tender Water Capacity (gals / ML) | 3000 / 11.36 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1500 / 5678 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 34 / 17 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 38 / 965 |
Boiler Pressure (psi / kPa) | 170 / 1170 |
High Pressure Cylinders (dia x stroke) (in / mm) | 16" x 20" / 406x508 |
Tractive Effort (lbs / kg) | 19,469 / 8831.00 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.21 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 122 - 2.25" / 57 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 15 / 4.57 |
Firebox Area (sq ft / m2) | 71 / 6.60 |
Grate Area (sq ft / m2) | 15.80 / 1.47 |
Evaporative Heating Surface (sq ft / m2) | 1143 / 106.23 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1143 / 106.23 |
Evaporative Heating Surface/Cylinder Volume | 245.58 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2686 |
Same as above plus superheater percentage | 2686 |
Same as above but substitute firebox area for grate area | 12,070 |
Power L1 | 3465 |
Power MT | 372.63 |