Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 44, p. 276. Works number was 33593 in July 1909.
Less than two years after buying its second small Baldwin Mogul (Locobase 9758), Spanish American Iron returned to the Philadelphia builder for a locomotive twice its size. A Mikado of middling proportions, it nonetheless represented a big jump in hauling power for the SAI.
But bigger plans were in the works; see Locobases 9157 and 14
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 60 |
Locobase ID | 12608 |
Railroad | Spanish-American Iron Company |
Country | Cuba |
Whyte | 2-8-2 |
Number in Class | 1 |
Road Numbers | 60 |
Gauge | Std |
Number Built | 1 |
Builder | Baldwin |
Year | 1909 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 13.08 / 3.99 |
Engine Wheelbase (ft / m) | 28 / 8.53 |
Ratio of driving wheelbase to overall engine wheelbase | 0.47 |
Overall Wheelbase (engine & tender) (ft / m) | 58 / 17.68 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 144,000 / 65,317 |
Engine Weight (lbs / kg) | 184,000 / 83,461 |
Tender Loaded Weight (lbs / kg) | 100,000 / 45,359 |
Total Engine and Tender Weight (lbs / kg) | 284,000 / 128,820 |
Tender Water Capacity (gals / ML) | 5000 / 18.94 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 60 / 30 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 48 / 1219 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 20" x 28" / 508x711 |
Tractive Effort (lbs / kg) | 35,700 / 16193.27 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.03 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 350 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 16.50 / 5.03 |
Firebox Area (sq ft / m2) | 180 / 16.72 |
Grate Area (sq ft / m2) | 54 / 5.02 |
Evaporative Heating Surface (sq ft / m2) | 3183 / 295.71 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 3183 / 295.71 |
Evaporative Heating Surface/Cylinder Volume | 312.64 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 9720 |
Same as above plus superheater percentage | 9720 |
Same as above but substitute firebox area for grate area | 32,400 |
Power L1 | 5775 |
Power MT | 353.66 |