Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 64, p. 396. Works number was 53858-53859, 53 in October 1920.
The official buyer of this trio of small oil-burning plantation Ten-wheelers was the West India Sugar Finance Corporation on behalf of the Atlantic Fruit Company. But all were delivered to the CT and operated on those rails in Oriente Province for decades. When the CT was nationalized after the 1959 Revolucion, the Central was renamed for Frank Pais and the first two were renumbered 1458-1459. Gene Connelly's Baldwin production list does not show what happened to the 6.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 4 |
Locobase ID | 14902 |
Railroad | Central Tanamo |
Country | Cuba |
Whyte | 4-6-0 |
Number in Class | 3 |
Road Numbers | 4-6 / 1458-1459 |
Gauge | Std |
Number Built | 3 |
Builder | Baldwin |
Year | 1920 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 9 / 2.74 |
Engine Wheelbase (ft / m) | 18.50 / 5.64 |
Ratio of driving wheelbase to overall engine wheelbase | 0.49 |
Overall Wheelbase (engine & tender) (ft / m) | 43.58 / 13.28 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 71,000 / 32,205 |
Engine Weight (lbs / kg) | 88,000 / 39,916 |
Tender Loaded Weight (lbs / kg) | 51,000 / 23,133 |
Total Engine and Tender Weight (lbs / kg) | 139,000 / 63,049 |
Tender Water Capacity (gals / ML) | 3000 / 11.36 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1200 / 4542 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 39 / 19.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 45 / 1143 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 15" x 22" / 381x559 |
Tractive Effort (lbs / kg) | 16,830 / 7633.97 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.22 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 176 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.66 / 3.55 |
Firebox Area (sq ft / m2) | 100 / 9.29 |
Grate Area (sq ft / m2) | 14.50 / 1.35 |
Evaporative Heating Surface (sq ft / m2) | 1166 / 108.36 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1166 / 108.36 |
Evaporative Heating Surface/Cylinder Volume | 259.13 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2610 |
Same as above plus superheater percentage | 2610 |
Same as above but substitute firebox area for grate area | 18,000 |
Power L1 | 4998 |
Power MT | 465.58 |