Data from A[nthony] E[dward] Durrant, The Steam Locomotives of Eastern Europe (Newton Abbot:David & Charles, 1966), amended and supplemented by Google translation of Czech Atlas website at [], last accessed 20 October 2011.
Ludvfk Schejbal made over several of the ex-Austrian 229 tank engines as they represented the largest class of passenger tanks in the new Czechoslovakia. His remake of this class required a strict adherence to a 14 metric tonne axle loading, so he added a second axle under the bunker to spread the weight.
Of all of the conversions, this quintet saw the longest service. The first withdrawal came in 1957 and the last in 1961.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 353.1 |
Locobase ID | 1641 |
Railroad | Czech State Rwy (CSD) |
Country | Czechoslovakia |
Whyte | 2-6-4T |
Number in Class | 5 |
Road Numbers | 353.101-353.105 |
Gauge | Std |
Number Built | |
Builder | |
Year | 1936 |
Valve Gear | |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | |
Engine Wheelbase (ft / m) | |
Ratio of driving wheelbase to overall engine wheelbase | |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 30,865 / 14,000 |
Weight on Drivers (lbs / kg) | 82,012 / 37,200 |
Engine Weight (lbs / kg) | 165,347 / 75,000 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 2508 / 9.50 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 4 / 4 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 46 / 23 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 62 / 1574 |
Boiler Pressure (psi / kPa) | 203.10 / 1400 |
High Pressure Cylinders (dia x stroke) (in / mm) | 15.35" x 28.35" / 390x720 |
Tractive Effort (lbs / kg) | 18,600 / 8436.83 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.41 |
Heating Ability | |
Tubes (number - dia) (in / mm) | |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | |
Firebox Area (sq ft / m2) | 101.18 / 9.40 |
Grate Area (sq ft / m2) | 21.53 / 2 |
Evaporative Heating Surface (sq ft / m2) | 974 / 90.50 |
Superheating Surface (sq ft / m2) | 324 / 30.10 |
Combined Heating Surface (sq ft / m2) | 1298 / 120.60 |
Evaporative Heating Surface/Cylinder Volume | 160.40 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 4373 |
Same as above plus superheater percentage | 5466 |
Same as above but substitute firebox area for grate area | 25,687 |
Power L1 | 15,193 |
Power MT | 1225.24 |