Varde-Grindsted Jernbane 2-6-2 Locomotives in Denmark


Class Details by Steve Llanso of Sweat House Media

Class 5 (Locobase 11250)

Data from William Bay, Danmarks Damplokomotiver (1977). [link] . Works number was 67 in 1925.

This 44.3-km (27.5-mile) line opened in 12 April 1919 with hand-me-down locomotives, so this was the first new-built locomotive operated by the railway. It was one of the smallest standard-gauge Prairie tanks to have been built for any service.

Principal Dimensions by Steve Llanso of Middle Run Media
Class5
Locobase ID11250
RailroadVarde-Grindsted Jernbane (VaGJ)
CountryDenmark
Whyte2-6-2T
Number in Class1
Road Numbers5
GaugeStd
Number Built1
BuilderFrichs
Year1925
Valve GearHeusinger
Locomotive Length and Weight
Driver Wheelbase (ft / m) 9.51 / 2.90
Engine Wheelbase (ft / m)32.48 / 9.90
Ratio of driving wheelbase to overall engine wheelbase 0.29
Overall Wheelbase (engine & tender) (ft / m)32.48 / 9.90
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)66,139 / 30,000
Engine Weight (lbs / kg)83,776 / 38,000
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)83,776 / 38,000
Tender Water Capacity (gals / ML)1320 / 5
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 2.50 / 2
Minimum weight of rail (calculated) (lb/yd / kg/m)37 / 18.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)43.30 / 1100
Boiler Pressure (psi / kPa)169.70 / 1170
High Pressure Cylinders (dia x stroke) (in / mm)14.17" x 21.26" / 360x540
Tractive Effort (lbs / kg)14,221 / 6450.54
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.65
Heating Ability
Tubes (number - dia) (in / mm)
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m)
Firebox Area (sq ft / m2)69.08 / 6.42
Grate Area (sq ft / m2)12.91 / 1.20
Evaporative Heating Surface (sq ft / m2)550 / 51.12
Superheating Surface (sq ft / m2)245 / 22.80
Combined Heating Surface (sq ft / m2)795 / 73.92
Evaporative Heating Surface/Cylinder Volume141.74
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation2191
Same as above plus superheater percentage2870
Same as above but substitute firebox area for grate area15,357
Power L19785
Power MT978.49

All material Copyright © SteamLocomotive.com
Wes Barris