Class Seth (Locobase 12566)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Vol 19, p 2. Works numbers were 13774 in September 1893, 13906 in January 1894, 14242 in March 1895, 18370 in November 1900, and 19691 in November 1901

Unlike the 1894 Ouija trio, which also operated in the Dominican Republic and are described in Locobase 12078, the Quisqueya engine burned "hard coal". The two designs differed only in the higher boiler-pressure setting of the 1901 "Seth".

Principal Dimensions by Steve Llanso of Middle Run Media
ClassSeth
Locobase ID12566
RailroadEstate Quisqueya
CountryDominican Republic
Whyte2-4-0
Number in Class1
Road Numbers4
Gauge2'6"
Number Built1
BuilderBurnham, Williams & Co
Year1901
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 3.75 / 1.14
Engine Wheelbase (ft / m) 9.75 / 2.97
Ratio of driving wheelbase to overall engine wheelbase 0.38
Overall Wheelbase (engine & tender) (ft / m)23.42 / 7.14
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)22,000 / 9979
Engine Weight (lbs / kg)27,000 / 12,247
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)600 / 2.27
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT)
Minimum weight of rail (calculated) (lb/yd / kg/m)18 / 9
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)30 / 762
Boiler Pressure (psi / kPa)150 / 930
High Pressure Cylinders (dia x stroke) (in / mm)9" x 14" / 229x356
Tractive Effort (lbs / kg)4820 / 2186.32
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.56
Heating Ability
Tubes (number - dia) (in / mm)70 - 1.5" / 38
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m) 8.08 / 2.46
Firebox Area (sq ft / m2)29 / 2.70
Grate Area (sq ft / m2) 6.50 / 0.60
Evaporative Heating Surface (sq ft / m2)252 / 23.42
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)252 / 23.42
Evaporative Heating Surface/Cylinder Volume244.46
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation975
Same as above plus superheater percentage975
Same as above but substitute firebox area for grate area4350
Power L12888
Power MT578.81