Consuelo Estate 2-6-0 Locomotives in the Dominican_Republic


Class Details by Steve Llanso of Sweat House Media

Class Planatito (Locobase 14480)

Data from DeGolyer, Vol 54, p. 245. Works numbers were 44062-44063 in September 1916.

These plantation Moguls were bought by the Bartram Brothers. At the time of their purchase, Consuelo was the biggest single sugar producer in the "Santo Domingo counsular district". From its base in Macoris District, the plantation generated 220,500 bags of sugar in 1916-1917.

The Planatitos and the Cachena had one of the smallest superheater installations possible. It was described as a top-header, double-loop system with smaller than usual diameters for the flues. The drier steam was admitted to the cylinders through 6" (152 mm) piston valves.

Principal Dimensions by Steve Llanso of Middle Run Media
ClassPlanatito
Locobase ID14480
RailroadConsuelo Estate
CountryDominican Republic
Whyte2-6-0
Number in Class2
Road Numbers9-10
Gauge2'6"
Number Built2
BuilderBaldwin
Year1916
Valve GearWalschaert
Locomotive Length and Weight
Driver Wheelbase (ft / m)7 / 2.13
Engine Wheelbase (ft / m)12.83 / 3.91
Ratio of driving wheelbase to overall engine wheelbase 0.55
Overall Wheelbase (engine & tender) (ft / m)35.54 / 10.83
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)39,000 / 17,690
Engine Weight (lbs / kg)45,500 / 20,638
Tender Loaded Weight (lbs / kg)35,000 / 15,876
Total Engine and Tender Weight (lbs / kg)80,500 / 36,514
Tender Water Capacity (gals / ML)1500 / 5.68
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 3.50 / 3
Minimum weight of rail (calculated) (lb/yd / kg/m)22 / 11
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)37 / 940
Boiler Pressure (psi / kPa)185 / 1280
High Pressure Cylinders (dia x stroke) (in / mm)12" x 16" / 305x406
Tractive Effort (lbs / kg)9792 / 4441.58
Factor of Adhesion (Weight on Drivers/Tractive Effort) 3.98
Heating Ability
Tubes (number - dia) (in / mm)48 - 1.75" / 44
Flues (number - dia) (in / mm)6 - 5" / 127
Flue/Tube length (ft / m)10.54 / 3.21
Firebox Area (sq ft / m2)42 / 3.90
Grate Area (sq ft / m2) 9.10 / 0.85
Evaporative Heating Surface (sq ft / m2)354 / 32.89
Superheating Surface (sq ft / m2)64
Combined Heating Surface (sq ft / m2)418 / 32.89
Evaporative Heating Surface/Cylinder Volume169.02
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1684
Same as above plus superheater percentage1936
Same as above but substitute firebox area for grate area8936
Power L16210
Power MT1053.13

All material Copyright © SteamLocomotive.com