Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 78, p. 121+. Works number was 58656 in September 1925.
This sugar estate was located in the Hato Mayor Province, which is on the narrowing peninsula northeast of Santo Domingo. This Consolidation burned "broken anthracite coal" and was certainly one of the smallest of the wheel arrangement to operate on the metre gauge. Its spec noted that its design should be "readily" convertible to oil firing and the spec spelled out how the tender should be able to carry 2,000 US gallons (7,570 litres).
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 5 |
Locobase ID | 15362 |
Railroad | Ingenio Las Pajas |
Country | Dominican Republic |
Whyte | 2-8-0 |
Number in Class | 1 |
Road Numbers | 5 |
Gauge | Metre |
Number Built | 1 |
Builder | Baldwin |
Year | 1925 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 10.50 / 3.20 |
Engine Wheelbase (ft / m) | 17 / 5.18 |
Ratio of driving wheelbase to overall engine wheelbase | 0.62 |
Overall Wheelbase (engine & tender) (ft / m) | 44.73 / 13.63 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 56,000 / 25,401 |
Engine Weight (lbs / kg) | 65,000 / 29,484 |
Tender Loaded Weight (lbs / kg) | 45,500 / 20,638 |
Total Engine and Tender Weight (lbs / kg) | 110,500 / 50,122 |
Tender Water Capacity (gals / ML) | 2000 / 7.58 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 5 / 5 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 23 / 11.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 36 / 914 |
Boiler Pressure (psi / kPa) | 180 / 1240 |
High Pressure Cylinders (dia x stroke) (in / mm) | 13" x 18" / 330x457 |
Tractive Effort (lbs / kg) | 12,929 / 5864.50 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.33 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 109 - 2" / 51 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 10 / 3.05 |
Firebox Area (sq ft / m2) | 68 / 6.32 |
Grate Area (sq ft / m2) | 12.60 / 1.17 |
Evaporative Heating Surface (sq ft / m2) | 634 / 58.90 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 634 / 58.90 |
Evaporative Heating Surface/Cylinder Volume | 229.27 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2268 |
Same as above plus superheater percentage | 2268 |
Same as above but substitute firebox area for grate area | 12,240 |
Power L1 | 3804 |
Power MT | 599.03 |