Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University, Volume 63, p. 32. Works number was 47490 in December 1917; 47608-47610, 47645-47646, 47670-47683, 47729 in January 1918; 47780-47793, 47854-47862, 47910-47913, 47934-47939 in February; 48005-48009, 48051-48052 in March.
Many of the railways in the British Empire benefited from the wartime largesse of the Briths War Mission in 1917-1918. In fulfilling the relatively large order of medium-sized Ten-wheelers, Baldwin seems to have offered, and had accepted, the superheated design recently delivered to the Escanaba & Lake Superior in February 1917 (Locobase 13810).
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 801 |
Locobase ID | 14592 |
Railroad | British War Mission/Egyptian State |
Country | Egypt |
Whyte | 4-6-0 |
Number in Class | 61 |
Road Numbers | 801, 811-870 |
Gauge | Std |
Number Built | 61 |
Builder | Baldwin |
Year | 1918 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 13.33 / 4.06 |
Engine Wheelbase (ft / m) | 24.75 / 7.54 |
Ratio of driving wheelbase to overall engine wheelbase | 0.54 |
Overall Wheelbase (engine & tender) (ft / m) | 54.35 / 16.57 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 37,250 / 16,896 |
Weight on Drivers (lbs / kg) | 108,600 / 49,260 |
Engine Weight (lbs / kg) | 142,600 / 64,682 |
Tender Loaded Weight (lbs / kg) | 120,000 / 54,431 |
Total Engine and Tender Weight (lbs / kg) | 262,600 / 119,113 |
Tender Water Capacity (gals / ML) | 6000 / 22.73 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 9.90 / 9 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 60 / 30 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 62 / 1575 |
Boiler Pressure (psi / kPa) | 190 / 1310 |
High Pressure Cylinders (dia x stroke) (in / mm) | 19" x 26" / 483x660 |
Tractive Effort (lbs / kg) | 24,449 / 11089.89 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.44 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 138 - 2" / 51 |
Flues (number - dia) (in / mm) | 22 - 5.375" / 137 |
Flue/Tube length (ft / m) | 14 / 4.27 |
Firebox Area (sq ft / m2) | 141 / 13.10 |
Grate Area (sq ft / m2) | 29.20 / 2.71 |
Evaporative Heating Surface (sq ft / m2) | 1578 / 146.60 |
Superheating Surface (sq ft / m2) | 366 / 34 |
Combined Heating Surface (sq ft / m2) | 1944 / 180.60 |
Evaporative Heating Surface/Cylinder Volume | 184.95 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5548 |
Same as above plus superheater percentage | 6602 |
Same as above but substitute firebox area for grate area | 31,880 |
Power L1 | 12,833 |
Power MT | 781.54 |