Exploitation agricole 0-4-0 Locomotives in France


Class Details by Steve Llanso of Sweat House Media

Class 211 (Locobase 7390)

Data from Titre Exposition universelle internationale de 1878 a Paris. Rapports du jury internationale..Volume Groupe VI - Classe 64. Rapport sur le materiel des chemins de fer. p. 55 (cnum.cnam.fr/CGI/fpage.cgi?8XAE277-11.1/54/100/312/0/0 (accessed 1 September 2005) table and page 91. Works numbers were 1920-1926 in 1875.

This tiny little tank was offered for "travaux agricole", agricultural work on a 31 1/2"-gauge railway. The only Cail 0-4-0Ts on the production list are the seven shown in 1875.

Principal Dimensions by Steve Llanso of Middle Run Media
Class211
Locobase ID7390
RailroadExploitation agricole
CountryFrance
Whyte0-4-0T
Number in Class1
Road Numbers1-7
Gauge80 cm
Number Built1
BuilderCail
Year1878
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 2.95 / 0.90
Engine Wheelbase (ft / m) 2.95 / 0.90
Ratio of driving wheelbase to overall engine wheelbase1
Overall Wheelbase (engine & tender) (ft / m) 2.95 / 0.90
Axle Loading (Maximum Weight per Axle) (lbs / kg)
Weight on Drivers (lbs / kg)8157 / 3700
Engine Weight (lbs / kg)8157 / 3700
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)
Tender Water Capacity (gals / ML)84 / 0.32
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) 0.20
Minimum weight of rail (calculated) (lb/yd / kg/m)7 / 3.50
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)23.60 / 599
Boiler Pressure (psi / kPa)130.50 / 900
High Pressure Cylinders (dia x stroke) (in / mm)5.91" x 9.45" / 150x240
Tractive Effort (lbs / kg)1551 / 703.52
Factor of Adhesion (Weight on Drivers/Tractive Effort) 5.26
Heating Ability
Tubes (number - dia) (in / mm)37 - 1.575" / 40
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m) 4.43 / 1.35
Firebox Area (sq ft / m2)12.27 / 1.14
Grate Area (sq ft / m2) 1.94 / 0.18
Evaporative Heating Surface (sq ft / m2)81 / 7.53
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)81 / 7.53
Evaporative Heating Surface/Cylinder Volume269.96
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation253
Same as above plus superheater percentage253
Same as above but substitute firebox area for grate area1601
Power L12435
Power MT1316.23