Data from A. Sampite, Les Chemins de Fer a Faible Trafic en France (Paris: Baudry et Cie, 1888), p. 49. See also [] for a history of these Freycinet Plan railways.
This Reseau d'Interet Local comprised 3 railways of which that of the Lyon a Saint-Genix-Aoste was by far the longest at 72 km (45 mi). The Sablonniere a Montalieu measured a mere 18 km and the Montalieu a Amblagnieu ran only 3 km.
Sampite notes the large grate in the Belpaire firebox and comments that it was intended to burn charcoal briquettes. The small drivers, he adds, limited maximum speeds to 50-53 km/h (31-31 1/2 mph), which was nonetheless speedy for such Feycinet Law railways. He also reported that these engines were giving excellent service.
The lines themselves, although built with 30-kg/metre (60-lb/yd) rail, were constructed to allow 70 km/h (43 mph) running. At the time of writing in 1888, Sampite reported that the railway was procuring new locomotives with 1,800-mm (70.9") drivers.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | unknown |
| Locobase ID | 9146 |
| Railroad | CF de l'Est de Lyon |
| Country | France |
| Whyte | 0-6-0T |
| Number in Class | 10 |
| Road Numbers | |
| Gauge | Std |
| Number Built | 10 |
| Builder | Couillet |
| Year | 1878 |
| Valve Gear | Stephenson |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 12.47 / 3.80 |
| Engine Wheelbase (ft / m) | 12.47 / 3.80 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 12.47 / 3.80 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | 28,660 / 13,000 |
| Weight on Drivers (lbs / kg) | 82,673 / 37,500 |
| Engine Weight (lbs / kg) | 82,673 / 37,500 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 46 / 23 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 55.90 / 1420 |
| Boiler Pressure (psi / kPa) | 130.50 / 900 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 16.93" x 23.62" / 430x600 |
| Tractive Effort (lbs / kg) | 13,434 / 6093.57 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 6.15 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | |
| Firebox Area (sq ft / m2) | 75.32 / 7 |
| Grate Area (sq ft / m2) | 22.38 / 2.08 |
| Evaporative Heating Surface (sq ft / m2) | 1076 / 100 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 1076 / 100 |
| Evaporative Heating Surface/Cylinder Volume | 174.84 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 2921 |
| Same as above plus superheater percentage | 2921 |
| Same as above but substitute firebox area for grate area | 9829 |
| Power L1 | 2870 |
| Power MT | 229.60 |