Data from SACM diagram Nr. 82 from Societe Alsacienne de Constructions Mecaniques from locomotive book supplied by Dany Machi up at [] as
Diagrammes des machines SACM construites a GRAFENSTADEN (October 2007).
Tube diameter is the interior measurement. Small industrial tank that served this large coal producer in Lyon. The design was very short-coupled
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 15533 |
Railroad | Houilleres de Saint-Etienne |
Country | France |
Whyte | 0-6-0T |
Number in Class | |
Road Numbers | |
Gauge | Std |
Number Built | |
Builder | SACM |
Year | 1888 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 5.74 / 1.75 |
Engine Wheelbase (ft / m) | 5.74 / 1.75 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 5.74 / 1.75 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 28,440 / 12,900 |
Engine Weight (lbs / kg) | 28,440 / 12,900 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 28,440 / 12,900 |
Tender Water Capacity (gals / ML) | 356 / 1.35 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 16 / 8 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 31.50 / 800 |
Boiler Pressure (psi / kPa) | 127.60 / 880 |
High Pressure Cylinders (dia x stroke) (in / mm) | 9.45" x 18.11" / 240x460 |
Tractive Effort (lbs / kg) | 5569 / 2526.06 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.11 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 78 - 1.378" / 35 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 9.19 / 2.80 |
Firebox Area (sq ft / m2) | 23.25 / 2.16 |
Grate Area (sq ft / m2) | 4.41 / 0.41 |
Evaporative Heating Surface (sq ft / m2) | 282 / 26.17 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 282 / 26.17 |
Evaporative Heating Surface/Cylinder Volume | 191.82 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 563 |
Same as above plus superheater percentage | 563 |
Same as above but substitute firebox area for grate area | 2967 |
Power L1 | 1815 |
Power MT | 422.09 |