Data from Titre Exposition universelle internationale de 1889 a Paris. Rapports du jury internationale. Auteur - Volume France. Ministere du Commerce, de l'industrie. Picard, Alfred, ed. Volume Groupe VI - -Outillage et precedes des industries mecaniques. Electricite (5e partie) Classes 60 a 63. Rapport sur le materiel des chemins de fer. p. 304 ([] (accessed 1 September 2005).
The Jury report notes that the line for which this design was produced was steep and winding with maximum grades of 3.5% and 100 m minimum-radius curves. The valve gear was unusual in its two eccentrics and a counter-crank forged as part of the crank arm on the driving axle.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 7431 |
Railroad | Riom a Volvie |
Country | France |
Whyte | 0-6-0T |
Number in Class | |
Road Numbers | |
Gauge | Metre |
Number Built | |
Builder | Batignolles |
Year | 1889 |
Valve Gear | Rectilinear |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 8.73 / 2.66 |
Engine Wheelbase (ft / m) | 8.73 / 2.66 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 8.73 / 2.66 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 52,580 / 23,850 |
Engine Weight (lbs / kg) | 52,580 / 23,850 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 52,580 / 23,850 |
Tender Water Capacity (gals / ML) | 792 / 3 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.10 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 29 / 14.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 39.80 / 1010 |
Boiler Pressure (psi / kPa) | 145 / 1000 |
High Pressure Cylinders (dia x stroke) (in / mm) | 13.78" x 17.72" / 350x450 |
Tractive Effort (lbs / kg) | 10,420 / 4726.44 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.05 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 78 - 1.969" / 50 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 12.14 / 3.70 |
Firebox Area (sq ft / m2) | 39.06 / 3.63 |
Grate Area (sq ft / m2) | 7.64 / 0.71 |
Evaporative Heating Surface (sq ft / m2) | 527 / 48.94 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 527 / 48.94 |
Evaporative Heating Surface/Cylinder Volume | 172.29 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1108 |
Same as above plus superheater percentage | 1108 |
Same as above but substitute firebox area for grate area | 5664 |
Power L1 | 2271 |
Power MT | 285.66 |