Ligne D'Anvin a Calais 0-6-2 Locomotives in France


Class Details by Steve Llanso of Sweat House Media

Class unknown (Locobase 9234)

See M D Banderali,"Le Chemin de Fer a Voie Etroite D'Anvin a Calais", La Nature, Vol 11, No 499 (23 Decembre 1882), p. 69-70; and "Conditions d'Etablissement du Materiel Roulant de la Ligne de Hermes a Beaumont (Voie de 1m00)", Revue gTnTrale des chemins de fer, Volume 4, pp. 167-177.

In the highly detailed description of the Hermes a Beaumont locomotives, the author notes that the same design was then operating on the Anvin a Calais.

Principal Dimensions by Steve Llanso of Middle Run Media
Classunknown
Locobase ID9234
RailroadLigne D'Anvin a Calais
CountryFrance
Whyte0-6-2T
Number in Class8
Road Numbers
GaugeMetre
Number Built8
BuilderSACM
Year1882
Valve GearStephenson
Locomotive Length and Weight
Driver Wheelbase (ft / m) 6.79 / 2.07
Engine Wheelbase (ft / m)13.02 / 3.97
Ratio of driving wheelbase to overall engine wheelbase 0.52
Overall Wheelbase (engine & tender) (ft / m)13.02 / 3.97
Axle Loading (Maximum Weight per Axle) (lbs / kg) / 6800
Weight on Drivers (lbs / kg)44,092 / 20,000
Engine Weight (lbs / kg)52,249 / 23,700
Tender Loaded Weight (lbs / kg)
Total Engine and Tender Weight (lbs / kg)52,249 / 23,700
Tender Water Capacity (gals / ML) / 3
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) / 1
Minimum weight of rail (calculated) (lb/yd / kg/m)24 / 12
Geometry Relating to Tractive Effort
Driver Diameter (in / mm)35.40 / 900
Boiler Pressure (psi / kPa)120.40 / 830
High Pressure Cylinders (dia x stroke) (in / mm)13.78" x 18.11" / 350x460
Tractive Effort (lbs / kg)9942 / 4509.62
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.43
Heating Ability
Tubes (number - dia) (in / mm) / 41
Flues (number - dia) (in / mm)
Flue/Tube length (ft / m) / 3.17
Firebox Area (sq ft / m2)43.04 / 4
Grate Area (sq ft / m2)10.76 / 1
Evaporative Heating Surface (sq ft / m2)583 / 54.22
Superheating Surface (sq ft / m2)
Combined Heating Surface (sq ft / m2)583 / 54.22
Evaporative Heating Surface/Cylinder Volume186.50
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation1296
Same as above plus superheater percentage1296
Same as above but substitute firebox area for grate area5182
Power L11814
Power MT272.10

All material Copyright © SteamLocomotive.com
Wes Barris