Data from "Locomotives Type 151A.A & L (G16)" supplied by "papyglob" on 20 July 2011 to the Les Trains de l'Histoire blog at [], last accessed 2 November 2011.
Perhaps aspiring to the same impressive levels of tractive effort as the 151As of the PLM (Locobase 2503), the two engines of the Alsace-Lorraine came a few years later and had three large simple-expansion cylinders and smaller drivers. The firebox had a combustion chamber and a CAIP feedwater heater, ACIF water-treatment system, and Kylchap double-chimney were fitted. The rear bissel truck held a booster that assisted starting effort until the locomotive had reached 30 km/h (18.6 mph).
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | G16 / 151A |
Locobase ID | 13351 |
Railroad | Alsace-Lorraine |
Country | France |
Whyte | 2-10-2 |
Number in Class | 2 |
Road Numbers | 5901-5902 |
Gauge | Std |
Number Built | 2 |
Builder | SACM |
Year | 1936 |
Valve Gear | Caprotti |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 21.39 / 6.52 |
Engine Wheelbase (ft / m) | 39.90 / 12.16 |
Ratio of driving wheelbase to overall engine wheelbase | 0.54 |
Overall Wheelbase (engine & tender) (ft / m) | 70.54 / 21.50 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 44,092 / 20,000 |
Weight on Drivers (lbs / kg) | 220,462 / 100,000 |
Engine Weight (lbs / kg) | 295,419 / 134,000 |
Tender Loaded Weight (lbs / kg) | 139,993 / 63,500 |
Total Engine and Tender Weight (lbs / kg) | 435,412 / 197,500 |
Tender Water Capacity (gals / ML) | 6600 / 25 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 7.70 / 7 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 73 / 36.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 59.10 / 1500 |
Boiler Pressure (psi / kPa) | 290.10 / 2000 |
High Pressure Cylinders (dia x stroke) (in / mm) | 22.64" x 28.35" / 575x720 (3) |
Tractive Effort (lbs / kg) | 90,944 / 41251.55 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 2.42 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 138 - 2.165" / 55 |
Flues (number - dia) (in / mm) | 35 - 5.827" / 148 |
Flue/Tube length (ft / m) | 19.39 / 5.91 |
Firebox Area (sq ft / m2) | 270.39 / 25.12 |
Grate Area (sq ft / m2) | 53.82 / 5 |
Evaporative Heating Surface (sq ft / m2) | 2639 / 245.19 |
Superheating Surface (sq ft / m2) | 1092 / 101.47 |
Combined Heating Surface (sq ft / m2) | 3731 / 346.66 |
Evaporative Heating Surface/Cylinder Volume | 133.19 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 15,613 |
Same as above plus superheater percentage | 20,141 |
Same as above but substitute firebox area for grate area | 101,188 |
Power L1 | 19,929 |
Power MT | 996.45 |