Data from SACM diagram Nr. 75 from Societe Alsacienne de Constructions Mecaniques from locomotive book supplied by Dany Machi up at [] as
Diagrammes des machines SACM construites a GRAFENSTADEN (October 2007).
Tube diameter is the interior measurement.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 15506 |
Railroad | Alsace-Lorraine |
Country | France |
Whyte | 2-4-0T |
Number in Class | |
Road Numbers | |
Gauge | Std |
Number Built | |
Builder | SACM |
Year | |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 6.89 / 2.10 |
Engine Wheelbase (ft / m) | 12.53 / 3.82 |
Ratio of driving wheelbase to overall engine wheelbase | 0.55 |
Overall Wheelbase (engine & tender) (ft / m) | 12.53 / 3.82 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | |
Engine Weight (lbs / kg) | 57,541 / 26,100 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 792 / 3 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 1.10 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 49.20 / 1250 |
Boiler Pressure (psi / kPa) | 159.50 / 1100 |
High Pressure Cylinders (dia x stroke) (in / mm) | 12.6" x 19.69" / 320x500 |
Tractive Effort (lbs / kg) | 8614 / 3907.25 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
Heating Ability | |
Tubes (number - dia) (in / mm) | 138 - 1.811" / 46 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 9.32 / 2.84 |
Firebox Area (sq ft / m2) | 47.36 / 4.40 |
Grate Area (sq ft / m2) | 12.38 / 1.15 |
Evaporative Heating Surface (sq ft / m2) | 591 / 54.90 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 591 / 54.90 |
Evaporative Heating Surface/Cylinder Volume | 207.98 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1975 |
Same as above plus superheater percentage | 1975 |
Same as above but substitute firebox area for grate area | 7554 |
Power L1 | 3810 |
Power MT |