Data from info published on [] (visited November 2002) by Roland Arzul, and data from I N Jevica's [
] (visited 29 May 2004).
Arzul says these locomotives essentially were copies of the PO 1701s (Locobase 3913) and the Sud 1301 (Locobase 3914). The data show a somewhat smaller locomotive, however. The Belpaire firebox is prominent.
[], a history of all the major regional lines visited 26 Nov 2004, says that the Ouest bought the first 10 in 1901 from Fives-Lille, the next 20 in 1902 from Cail, and the last 10 in 1906 from Fives-Lille. When the Etat assumed control of the Ouest, it finished off this class with 15 more from Schneider in 1909.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 3700 / 230-001 / 230B |
Locobase ID | 6061 |
Railroad | Ouest / Etat |
Country | France |
Whyte | 4-6-0 |
Number in Class | 55 |
Road Numbers | 3701-3755/230-001 a 230-055 |
Gauge | Std |
Number Built | 55 |
Builder | several |
Year | 1901 |
Valve Gear | Walschaert |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | |
Engine Wheelbase (ft / m) | |
Ratio of driving wheelbase to overall engine wheelbase | |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | / 43,700 |
Engine Weight (lbs / kg) | 130,954 / 59,400 |
Tender Loaded Weight (lbs / kg) | 84,000 |
Total Engine and Tender Weight (lbs / kg) | 214,954 |
Tender Water Capacity (gals / ML) | 3960 / 15 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 6.60 / 6 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 68.90 / 1750 |
Boiler Pressure (psi / kPa) | 217.60 / 1500 |
High Pressure Cylinders (dia x stroke) (in / mm) | 13.78" x 25.2" / 350x640 |
Low Pressure Cylinders (dia x stroke) (in / mm) | 21.65" x 25.2" / 550x640 |
Tractive Effort (lbs / kg) | 18,284 / 8293.49 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | |
Heating Ability | |
Tubes (number - dia) (in / mm) | |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | |
Firebox Area (sq ft / m2) | / 13.41 |
Grate Area (sq ft / m2) | 25.82 / 2.40 |
Evaporative Heating Surface (sq ft / m2) | 1826 / 169.73 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1826 / 169.73 |
Evaporative Heating Surface/Cylinder Volume | 419.78 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 5618 |
Same as above plus superheater percentage | 5618 |
Same as above but substitute firebox area for grate area | |
Power L1 | |
Power MT |