Data from Ernest Taillard, Exposition Universelle de Paris de 1867-Chemins de Fer-Les Locomotives et le Materiel de Transport, 1ie Volume (Paris: Dunod, 1867), pp. 27-31.
As the driver diameter suggests, this was a mixed-traffic locomotive. According to Taillard, among other features was the lack of pumps for feeding water into the boiler; instead, the engine used two Krauss injectors, which were unequal to the task. The firebox was a coke-burner that had two stages, the exhaust was variable, and the two safety-balves were fixed, one on the dome and the other on the firebox.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | unknown |
Locobase ID | 11287 |
Railroad | |
Country | Prussia |
Whyte | 0-4-2 |
Number in Class | |
Road Numbers | |
Gauge | Std |
Number Built | |
Builder | Borsig |
Year | 1867 |
Valve Gear | Stephenson |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | |
Engine Wheelbase (ft / m) | 13.39 / 4.08 |
Ratio of driving wheelbase to overall engine wheelbase | |
Overall Wheelbase (engine & tender) (ft / m) | |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 27,007 / 12,250 |
Weight on Drivers (lbs / kg) | 50,706 / 23,000 |
Engine Weight (lbs / kg) | 73,414 / 33,300 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 42 / 21 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 60 / 1524 |
Boiler Pressure (psi / kPa) | 116 / 800 |
High Pressure Cylinders (dia x stroke) (in / mm) | 15.98" x 22.01" / 406x559 |
Tractive Effort (lbs / kg) | 9236 / 4189.38 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.49 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 194 - 1.811" / 46 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 11.32 / 3.45 |
Firebox Area (sq ft / m2) | 72.85 / 6.77 |
Grate Area (sq ft / m2) | 18.51 / 1.72 |
Evaporative Heating Surface (sq ft / m2) | 1001 / 93.07 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 1001 / 93.07 |
Evaporative Heating Surface/Cylinder Volume | 195.92 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 2147 |
Same as above plus superheater percentage | 2147 |
Same as above but substitute firebox area for grate area | 8451 |
Power L1 | 3100 |
Power MT | 269.57 |