Data from [] (last accessed 1 September 2008).
These little tanks arrived in pairs and singles as demand increased. The first two served the original 5.2-km (3.2 mile) line beginning in 1885 and were joined by a third in 1892. A significant lengthening in the mid-1890s of 30 km prompted an order for two more.
They served the need for more than three decades, in the process acquiring a slightly larger boiler that is depicted in the specifications. Two were withdrawn before 1932. Conversion of the route to standard-gauge operation doomed the other three in 1935.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | LE / BR 99.07 |
Locobase ID | 9545 |
Railroad | Bavarian - EichstStt-Stadt & EichstStt-Bahnhof |
Country | Germany |
Whyte | 0-6-0T |
Number in Class | 5 |
Road Numbers | 1-5, 99.071-99 075 |
Gauge | Std |
Number Built | 5 |
Builder | Krauss |
Year | 1885 |
Valve Gear | Allan |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 5.91 / 1.80 |
Engine Wheelbase (ft / m) | 5.91 / 1.80 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 5.91 / 1.80 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 34,833 / 15,800 |
Weight on Drivers (lbs / kg) | 38,515 / 17,470 |
Engine Weight (lbs / kg) | 38,515 / 17,470 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 38,515 / 17,470 |
Tender Water Capacity (gals / ML) | 467 / 1.77 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.70 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 21 / 10.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 31.50 / 800 |
Boiler Pressure (psi / kPa) | 171.10 / 1180 |
High Pressure Cylinders (dia x stroke) (in / mm) | 10.24" x 15.75" / 260x400 |
Tractive Effort (lbs / kg) | 7625 / 3458.65 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 5.05 |
Heating Ability | |
Tubes (number - dia) (in / mm) | |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | |
Firebox Area (sq ft / m2) | 28.30 / 2.63 |
Grate Area (sq ft / m2) | 5.70 / 0.53 |
Evaporative Heating Surface (sq ft / m2) | 346 / 32.20 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 346 / 32.20 |
Evaporative Heating Surface/Cylinder Volume | 230.47 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 975 |
Same as above plus superheater percentage | 975 |
Same as above but substitute firebox area for grate area | 4842 |
Power L1 | 2917 |
Power MT | 500.91 |