Data from Alfred Gieseler, "Baureihe 99 4511" on his Dampfmaschinen und Lokomotiven website at [], last accessed 4 November 2020. See also [], last accessed 14 May 2011.
The 3 was delivered as an 0-6-2T in 1899 (Locobase 12578) along with two sisters. Decades later, according to Wikipedia, the 3 was rebuilt by East Germany's DDR at their Gorlitz Works as an 0-6-0T on a new frame with a new boiler, axles, and cab.
Retired on 5 November 1976, the 3 was immediately placed in museum service at the Holiday Park in Hassloch. It moved to IG Pre+nitztalbahn in Jÿhstadt in 1998.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | BR 99 4511 |
Locobase ID | 6540 |
Railroad | Rathenow-Senske-Nauen KB |
Country | Germany |
Whyte | 0-6-0T |
Number in Class | 1 |
Road Numbers | 99 4511 |
Gauge | 75 cm |
Number Built | |
Builder | RAW Gorlitz |
Year | 1966 |
Valve Gear | Heusinger |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 10.83 / 3.30 |
Engine Wheelbase (ft / m) | 10.83 / 3.30 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 10.83 / 3.30 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
Weight on Drivers (lbs / kg) | 30,865 / 14,000 |
Engine Weight (lbs / kg) | 30,865 / 14,000 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | 30,865 / 14,000 |
Tender Water Capacity (gals / ML) | 462 / 1.75 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.70 / 0.60 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 17 / 8.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 30.70 / 780 |
Boiler Pressure (psi / kPa) | 203.10 / 1400 |
High Pressure Cylinders (dia x stroke) (in / mm) | 9.84" x 12.99" / 250x330 |
Tractive Effort (lbs / kg) | 7073 / 3208.26 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.36 |
Heating Ability | |
Tubes (number - dia) (in / mm) | |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | |
Firebox Area (sq ft / m2) | 31.97 / 2.97 |
Grate Area (sq ft / m2) | 5.92 / 0.55 |
Evaporative Heating Surface (sq ft / m2) | 318 / 29.50 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 318 / 29.50 |
Evaporative Heating Surface/Cylinder Volume | 278.13 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1202 |
Same as above plus superheater percentage | 1202 |
Same as above but substitute firebox area for grate area | 6493 |
Power L1 | 4343 |
Power MT | 930.63 |