Data from Alfred Gieseler, "Baureihe 99 4511" on his Dampfmaschinen und Lokomotiven website at [], last accessed 4 November 2020. See also [], last accessed 14 May 2011.
The 3 was delivered as an 0-6-2T in 1899 (Locobase 12578) along with two sisters. Decades later, according to Wikipedia, the 3 was rebuilt by East Germany's DDR at their Gorlitz Works as an 0-6-0T on a new frame with a new boiler, axles, and cab.
Retired on 5 November 1976, the 3 was immediately placed in museum service at the Holiday Park in Hassloch. It moved to IG Pre+nitztalbahn in Jÿhstadt in 1998.
| Principal Dimensions by Steve Llanso of Middle Run Media | |
|---|---|
| Class | BR 99 4511 |
| Locobase ID | 6540 |
| Railroad | Rathenow-Senske-Nauen KB |
| Country | Germany |
| Whyte | 0-6-0T |
| Number in Class | 1 |
| Road Numbers | 99 4511 |
| Gauge | 75 cm |
| Number Built | |
| Builder | RAW Gorlitz |
| Year | 1966 |
| Valve Gear | Heusinger |
| Locomotive Length and Weight | |
| Driver Wheelbase (ft / m) | 10.83 / 3.30 |
| Engine Wheelbase (ft / m) | 10.83 / 3.30 |
| Ratio of driving wheelbase to overall engine wheelbase | 1 |
| Overall Wheelbase (engine & tender) (ft / m) | 10.83 / 3.30 |
| Axle Loading (Maximum Weight per Axle) (lbs / kg) | |
| Weight on Drivers (lbs / kg) | 30,865 / 14,000 |
| Engine Weight (lbs / kg) | 30,865 / 14,000 |
| Tender Loaded Weight (lbs / kg) | |
| Total Engine and Tender Weight (lbs / kg) | |
| Tender Water Capacity (gals / ML) | 462 / 1.75 |
| Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.70 / 0.60 |
| Minimum weight of rail (calculated) (lb/yd / kg/m) | 17 / 8.50 |
| Geometry Relating to Tractive Effort | |
| Driver Diameter (in / mm) | 30.70 / 780 |
| Boiler Pressure (psi / kPa) | 203.10 / 1400 |
| High Pressure Cylinders (dia x stroke) (in / mm) | 9.84" x 12.99" / 250x330 |
| Tractive Effort (lbs / kg) | 7073 / 3208.26 |
| Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.36 |
| Heating Ability | |
| Tubes (number - dia) (in / mm) | |
| Flues (number - dia) (in / mm) | |
| Flue/Tube length (ft / m) | |
| Firebox Area (sq ft / m2) | 31.97 / 2.97 |
| Grate Area (sq ft / m2) | 5.92 / 0.55 |
| Evaporative Heating Surface (sq ft / m2) | 318 / 29.50 |
| Superheating Surface (sq ft / m2) | |
| Combined Heating Surface (sq ft / m2) | 318 / 29.50 |
| Evaporative Heating Surface/Cylinder Volume | 278.13 |
| Computations Relating to Power Output (More Information) | |
| Robert LeMassena's Power Computation | 1202 |
| Same as above plus superheater percentage | 1202 |
| Same as above but substitute firebox area for grate area | 6493 |
| Power L1 | 4343 |
| Power MT | 930.63 |