Data from Paul Dorscheimer's website -- [], accessed 22 May 2006 (recast as
[], last accessed 8 October 2022. Other information from the Westerwald region website article on the surviving #2 -- [
], 100 Jahre Dampflok Nr. 2, accessed 25 May 2006. Works numbers were 5574-5576 in 1900.
More than 50 years of service on the Selters KB included passenger and freight hauling along the 24-km (14.9 miles) railway. In October 1957 the Nassaui Kleinbahn AG bought the short-coupled six-coupled as their #16 (the II) -- (See Locobase 3785 for more information on the NKAG.). When the last of the Taunus-area line was closed in 1962, #2 lingered in limbo for many years, but was eventually plinthed in Nastatten.
Principal Dimensions by Steve Llanso of Middle Run Media | |
---|---|
Class | 1/16 II |
Locobase ID | 7500 |
Railroad | Selters-Hachenburg Kleinbahn |
Country | Germany |
Whyte | 0-6-0T |
Number in Class | 3 |
Road Numbers | 1-3 |
Gauge | Metre |
Number Built | 3 |
Builder | Henschel & Sohn |
Year | 1900 |
Valve Gear | Allan |
Locomotive Length and Weight | |
Driver Wheelbase (ft / m) | 7.38 / 2.25 |
Engine Wheelbase (ft / m) | 7.38 / 2.25 |
Ratio of driving wheelbase to overall engine wheelbase | 1 |
Overall Wheelbase (engine & tender) (ft / m) | 7.38 / 2.25 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | 18,519 / 8400 |
Weight on Drivers (lbs / kg) | 55,116 / 25,000 |
Engine Weight (lbs / kg) | 55,116 / 25,000 |
Tender Loaded Weight (lbs / kg) | |
Total Engine and Tender Weight (lbs / kg) | |
Tender Water Capacity (gals / ML) | 792 / 3 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 2.20 / 2 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | 31 / 15.50 |
Geometry Relating to Tractive Effort | |
Driver Diameter (in / mm) | 35.80 / 910 |
Boiler Pressure (psi / kPa) | 174 / 1200 |
High Pressure Cylinders (dia x stroke) (in / mm) | 11.81" x 19.69" / 300x500 |
Tractive Effort (lbs / kg) | 11,346 / 5146.47 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | 4.86 |
Heating Ability | |
Tubes (number - dia) (in / mm) | 118 - 1.772" / 45 |
Flues (number - dia) (in / mm) | |
Flue/Tube length (ft / m) | 9.35 / 2.85 |
Firebox Area (sq ft / m2) | |
Grate Area (sq ft / m2) | 8.83 / 0.82 |
Evaporative Heating Surface (sq ft / m2) | 508 / 47.20 |
Superheating Surface (sq ft / m2) | |
Combined Heating Surface (sq ft / m2) | 508 / 47.20 |
Evaporative Heating Surface/Cylinder Volume | 203.49 |
Computations Relating to Power Output (More Information) | |
Robert LeMassena's Power Computation | 1536 |
Same as above plus superheater percentage | 1536 |
Same as above but substitute firebox area for grate area | |
Power L1 | |
Power MT |