Data from [], last accessed 14 May 2011. For the RSN, see [
] (Locobase availed himself of Google's translation.) Works numbers were 4111-4113 in 1899.
Data from Christian Lindecke's [] (visited 27 May 2005). See also [
], last accessed 11 April 1 2010. O & K works numbers were 845-846 in 1901.
Principal Dimensions by Steve Llanso of Sweat House Media | ||
---|---|---|
Class | K34.5 / 99 4511 | K34.5 / 99 4512 |
Locobase ID | 12578 | 6541 |
Railroad | Rathenow-Senske-Nauen KB | Rathenow-Senske-Nauen KB |
Country | Germany | Germany |
Whyte | 0-6-2T | 0-6-2T |
Number in Class | 3 | 2 |
Road Numbers | 1-3 / 99 4511-99 4513 | 4-5 / 99 4512 |
Gauge | 75 cm | 75 cm |
Number Built | 3 | 2 |
Builder | Krauss | Orenstein & Koppel |
Year | 1899 | 1901 |
Valve Gear | Heusinger | Lenker |
Locomotive Length and Weight | ||
Driver Wheelbase (ft / m) | ||
Engine Wheelbase (ft / m) | 10.83 / 3.30 | 9.65 / 2.94 |
Ratio of driving wheelbase to overall engine wheelbase | ||
Overall Wheelbase (engine & tender) (ft / m) | 10.83 / 3.30 | 9.65 / 2.94 |
Axle Loading (Maximum Weight per Axle) (lbs / kg) | ||
Weight on Drivers (lbs / kg) | ||
Engine Weight (lbs / kg) | 30,865 / 14,000 | 28,660 / 13,000 |
Tender Loaded Weight (lbs / kg) | ||
Total Engine and Tender Weight (lbs / kg) | 30,865 / 14,000 | 28,660 / 13,000 |
Tender Water Capacity (gals / ML) | 462 / 1.75 | 422 / 1.60 |
Tender Fuel Capacity (oil/coal) (gals/tons / Liters/MT) | 0.70 / 1 | 0.70 / 1 |
Minimum weight of rail (calculated) (lb/yd / kg/m) | ||
Geometry Relating to Tractive Effort | ||
Driver Diameter (in / mm) | 26.80 / 680 | 27.60 / 700 |
Boiler Pressure (psi / kPa) | 174 / 12 | 174 / 12 |
High Pressure Cylinders (dia x stroke) (in / mm) | 10.24" x 11.81" / 260x300 | 10.24" x 13.78" / 260x350 |
Tractive Effort (lbs / kg) | 6834 / 3099.85 | 7743 / 3512.17 |
Factor of Adhesion (Weight on Drivers/Tractive Effort) | ||
Heating Ability | ||
Tubes (number - dia) (in / mm) | ||
Flues (number - dia) (in / mm) | ||
Flue/Tube length (ft / m) | ||
Firebox Area (sq ft / m2) | 31.96 / 2.97 | 31.20 / 2.90 |
Grate Area (sq ft / m2) | 5.92 / 0.55 | 6.67 / 0.62 |
Evaporative Heating Surface (sq ft / m2) | 317 / 29.50 | 336 / 31.20 |
Superheating Surface (sq ft / m2) | ||
Combined Heating Surface (sq ft / m2) | 317 / 29.50 | 336 / 31.20 |
Evaporative Heating Surface/Cylinder Volume | 281.60 | 255.81 |
Computations Relating to Power Output (More Information) | ||
Robert LeMassena's Power Computation | 1030 | 1161 |
Same as above plus superheater percentage | 1030 | 1161 |
Same as above but substitute firebox area for grate area | 5561 | 5429 |
Power L1 | 3292 | 2998 |
Power MT |